2–43

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

FCC

Pressure Control Limits

Word

Description

FCC41

Pressure Minimum Control Limit [02] Minimum controllable clamp pressure attainable during any Press/Pos First Clamp Close Pro-
file. The module expects this clamp pressure when setting its selected pressure valve to the%-output in FCC43.

FCC42

Pressure Maximum Control Limit [02] Maximum controllable clamp pressure attainable during any Press/Pos First Clamp Close
Profile. The module expects this clamp pressure when setting its selected pressure valve to the%-output in FCC44.

FCC43

Selected Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pressure
valveduring any Press/Pos First Clamp Close Profile. The module expects a pressure equal to FCC41 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos First Clamp Close Profile will be executed as a reverse-act-
ing algorithm if this entry is greater than FCC44.

FCC44

Selected Pressure Valve Output for Maximum [19] 100% CV output percentage that Module uses to drive the selected pressure
valveduring any Press/Pos First Clamp Close Profile. The module expects a pressure equal to FCC42 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos First Clamp Close Profile will be executed as a reverse-act-
ing algorithm if this entry is less than FCC43.

Velocity Control Limits

Word

Description

FCC45

Velocity Minimum Control Limit [08] Minimum controllable clamp velocity attainable during any Vel/Pos First Clamp Close Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in FCC47.

FCC46

Velocity Maximum Control Limit [08] Maximum controllable clamp velocity attainable during any Vel/Pos First Clamp Close Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in FCC48.

FCC47

Selected Velocity Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected velocity valve
during anyVel/Pos First Clamp Close Profile. The module expects a velocity equal to FCC45 when setting the selected velocity
valve to this %-output during profile execution. The Vel/Pos First ClampClose Profile will be executed as a reverse-acting algorithm
if this entry is greater than FCC48.

FCC48

Selected Velocity Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected velocity
valve during any Vel/Pos First Clamp Close Profile. The module expects a velocity equal to FCC46 when setting the selected veloc-
ity valve to this %-output during profile execution. The Vel/Pos First Clamp Close Profile will be executed as a reverse-acting algo-
rithm if this entry is less than FCC47.

Profile Tuning Constants

Word

Description

FCC49

Proportional Gain for Pressure Control [30]

FCC50

Integral Gain for Pressure Control [27] or [28]

FCC51

Derivative Gain for Pressure Control [26] or [21]

FCC52

Proportional Gain for Velocity Control [28]

FCC53

Feed Forward Gain for Velocity Control [30]

FCC54 - 56

Open

Profile Pressure Alarm Setpoint

Word

Description

FCC57

Profile High Pressure Alarm Setpoint [02] The module compares real-time clamp pressure against this entry when executing the
First Clamp Close Profile. The module sets alarm status bit SYS05-B12 when clamp pressure equals or exceeds this entry during
the First Clamp Close Profile. A zero entry inhibits SYS05-B12.

FCC58 - 64