Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

Bit

B12

= 0 Vel/Pos Third Clamp Open Profiles ERC On
= 1 Vel/Pos Third Clamp Open Profiles ERC Off

B13

= 0 Press/Pos Third Clamp Open Profiles ERC On
= 1 Press/Pos Third Clamp Open Profiles ERC Off

B14

= 0 Vel/Pos Clamp Open Slow Profiles ERC On
= 1 Vel/Pos Clamp Open Slow Profiles ERC Off

B15

= 0 Press/Pos Clamp Open Slow Profiles ERC On
= 1 Press/Pos Clamp Open Slow Profiles ERC Off

OPC05 - 08

Open

First Clamp Open Profile Setpoints

Word

Description

OPC09

Segment 1 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp open speed to this setpoint after starting the First Clamp Open Profile
until clamp position reaches the smaller of non-zero OPC11 or OPC61

OPC03-B14 is RESET

reads this parameter in percent velocity

OPC03-B14 is SET

reads it in in.(mm)/s.

OPC10

Segment 1 Pressure Setpoint [02] If you select Press/Pos profile execution, the module controls clamp open pressure to this set-
point after starting the First Clamp Open Profile until clamp position reaches the smaller of non-zero OPC11 or OPC61.

OPC11

End of Segment 1 Position Setpoint [14]

OPC12

Segment 2 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp open speed to this setpoint from the clamp position OPC11 until clamp
position reaches the smaller of non-zero OPC14 or OPC61

OPC03-B14 is RESET

reads this parameter in percent velocity

OPC03-B14 is SET

reads it in in.(mm)/s

OPC13

Segment 2 Pressure Setpoint [02] If you select Press/Pos profile execution, the module controls clamp open pressure to this set-
point from the clamp position OPC11 until clamp position reaches the smaller of non-zero OPC14 or OPC61.

OPC14

End of Segment 2 Position Setpoint [14]

OPC15

Segment 3 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp open speed to this setpoint from the clamp position OPC14 until clamp
position reaches the smaller of non-zero OPC17 or OPC61

OPC03-B14 is RESET

reads this parameter in percent velocity

OPC03-B14 is SET

reads it in in.(mm)/s

OPC16

Segment 3 Pressure Setpoint [02] If you select Press/Pos profile execution, the module controls clamp open pressure to this set-
point from the clamp position OPC14 until clamp position reaches the smaller of non-zero OPC17 or OPC61.

OPC17

End of Segment 3 Position Setpoint [14]

Second Clamp Open Profile Setpoints

Word

Description

OPC18

Segment 4 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp open speed to this setpoint after starting the Second Clamp Open Profile
until clamp position reaches the smaller of non-zero OPC20 or OPC61

OPC03-B14 is RESET

reads this parameter in percent velocity

OPC03-B14 is SET

reads it in in.(mm)/s

OPC19

Segment 4 Pressure Setpoint [02] If you select Press/Pos profile execution, the module controls clamp open pressure to this set-
point after starting the Second Clamp Open Profile until clamp position reaches the smaller of non-zero OPC20 or OPC61.

OPC20

End of Segment 4 Position Setpoint [14]