2–106

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

TCC17

Output #1 Acceleration Ramp Rate during Profile [20]

TCC25

Output #1 Deceleration Ramp Rate during Profile [20]

TCC26

Output #2 Deceleration Ramp Rate during Profile [20]

TCC27

Output #3 Deceleration Ramp Rate during Profile [20]

TCC28

Output #4 Deceleration Ramp Rate during Profile [20]

TCC29

Output #5 Deceleration Ramp Rate during Profile [20]

TCC30

Output #6 Deceleration Ramp Rate during Profile [20]

TCC31

Output #7 Deceleration Ramp Rate during Profile [20]

TCC32

Output #8 Deceleration Ramp Rate during Profile [20]

End of Profile Set-output Values

When the module completes the Third Clamp Close Profile and
CPC03-B10 is set, it:

sets its outputs to the following values

sets status bit SYS22-B02

uses ramp rates TCC17 - 32 when changing outputs to these values

Use these values for setting cores if applied before starting the
Clamp Low Pressure Close Profile.

Word

Description

TCC33

Output #1 Set-output Value at End of Profile [19]

TCC34

Output #2 Set-output Value at End of Profile [19]

TCC35

Output #3 Set-output Value at End of Profile [19]

TCC36

Output #4 Set-output Value at End of Profile [19]

TCC37

Output #5 Set-output Value at End of Profile [19]

TCC38

Output #6 Set-output Value at End of Profile [19]

TCC39

Output #7 Set-output Value at End of Profile [19]

TCC40

Output #8 Set-output Value at End of Profile [19]

Pressure Control Limits

Word

Description

TCC41

Pressure Minimum Control Limit [02] Minimum controllable clamp pressure attainable during any Press/Pos Third Clamp Close
Profile. The module expects this clamp pressure when setting its selected pressure valve to the %-output in TCC43.

TCC42

Pressure Maximum Control Limit [02] Maximum controllable clamp pressure attainable during any Press/Pos Third Clamp Close
Profile. The module expects this clamp pressure when setting its selected pressure valve to the %-output in TCC44.

TCC43

Selected Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos Third Clamp Close Profile. The module expects a pressure equal to TCC41 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Third Clamp Close Profile will be executed as a reverse-act-
ing algorithm if this entry is greater than TCC44.

TCC44

Selected Pressure Valve Output for Maximum [19] 100% CV output percentage t hat the module uses to drive the selected pressure
valve during any Press/Pos Third Clamp Close Profile. The module expects a pressure equal to TCC42 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Third Clamp Close Profile will be executed as a reverse-act-
ing algorithm if this entry is less than TCC43.