Scc - second clamp close configuration block, Scc – second clamp close configuration block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 163

Advertising
background image

2–97

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

RLC

Pack Profile ERC Values

Word

Description

RLC20

Pack Segment 1

RLC21

Pack Segment 2

RLC22

Pack Segment 3

RLC23

Pack Segment 4

RLC24

Pack Segment 5

Hold Profile ERC Values

Word

Description

RLC25

Hold Segment 1

RLC26

Hold Segment 2

RLC27

Hold Segment 3

RLC28

Hold Segment 4

RLC29

Hold Segment 5

Plastication Profile ERC Values

Word

Description

RLC30

Plastication Segment 1

RLC31

Plastication Segment 2

RLC32

Plastication Segment 3

RLC33

Plastication Segment 4

RLC34

Plastication Segment 5

RLC35

Plastication Segment 6

RLC36

Plastication Segment 7

RLC37

Plastication Segment 8

RLC38

Plastication Segment 9

RLC39

Plastication Segment 10

RLC40

Plastication Segment 11

RLC41 - 64

Open

Bit-mapped Control Words

Word

Bit

Description

SCC01

Block ID = 00000100 (Low byte). High byte reserved for the module. Do not use.

SCC02

Configuration Selections

B00-B02

Selected Velocity Control Valve
The module uses its algorithm to drive the following output during any Vel/Pos Second Clamp Close Profile.
B02 B01 B00
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8

SCC – Second Clamp
Close Configuration Block