2–97
Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
RLC
Pack Profile ERC Values
Word
Description
RLC20
Pack Segment 1
RLC21
Pack Segment 2
RLC22
Pack Segment 3
RLC23
Pack Segment 4
RLC24
Pack Segment 5
Hold Profile ERC Values
Word
Description
RLC25
Hold Segment 1
RLC26
Hold Segment 2
RLC27
Hold Segment 3
RLC28
Hold Segment 4
RLC29
Hold Segment 5
Plastication Profile ERC Values
Word
Description
RLC30
Plastication Segment 1
RLC31
Plastication Segment 2
RLC32
Plastication Segment 3
RLC33
Plastication Segment 4
RLC34
Plastication Segment 5
RLC35
Plastication Segment 6
RLC36
Plastication Segment 7
RLC37
Plastication Segment 8
RLC38
Plastication Segment 9
RLC39
Plastication Segment 10
RLC40
Plastication Segment 11
RLC41 - 64
Open
Bit-mapped Control Words
Word
Bit
Description
SCC01
Block ID = 00000100 (Low byte). High byte reserved for the module. Do not use.
SCC02
Configuration Selections
B00-B02
Selected Velocity Control Valve
The module uses its algorithm to drive the following output during any Vel/Pos Second Clamp Close Profile.
B02 B01 B00
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8
SCC – Second Clamp
Close Configuration Block