4–14

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 7

0420

CPC20 is out of range.
if:

then:

MCC27 and MCC28

CPC20 must be within 00000

CPC20

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

CPC20 must be within 00000

CPC20

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

CPC20 must be within 00000

CPC20

MCC28 – MCC23

MCC28 is non-zero

MCC27 and MCC28

CPC20 must be within 00000

CPC20

MCC24 – MCC23

are both zero

0421

CPC21 is out of range. When CPC03-B14 = 1, a non-zero entry for CPC21 must be within
SCC45

CPC21

SCC46

0422

CPC22 is out of range. If non-zero, CPC22 must be within SCC41

CPC22

SCC42

0423

CPC23 is out of range.
if:

then:

MCC27 and MCC28

CPC23 must be within 00000

CPC23

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

CPC23 must be within 00000

CPC23

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

CPC23 must be within 00000

CPC23

MCC28 – MCC23.

MCC28 is non-zero

MCC27 and MCC28

CPC23 must be within 00000

CPC23

MCC24 – MCC23

are both zero

0424

CPC24 is out of range. When CPC03-B14 = 1, a non-zero entry for CPC24 must be within
SCC45

CPC24

SCC46

0425

CPC25 is out of range. If non-zero, CPC25 must be within SCC41

CPC25

SCC42

0426

CPC26 is out of range.
if:

then:

MCC27 and MCC28

CPC26 must be within 00000

CPC26

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

CPC26 must be within 00000

CPC26

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

CPC26 must be within 00000

CPC26

MCC28 – MCC23.

MCC28 is non-zero

MCC27 and MCC28

CPC26 must be within 00000

CPC26

MCC24 – MCC23

are both zero

0427

CPC27 is out of range. When CPC03-B14 = 1, a non-zero entry for CPC27 must be within
TCC45

CPC27

TCC46

0428

CPC28 is out of range. If non-zero, CPC28 must be within TCC41

CPC28

TCC42

0429

CPC29 is out of range.
if:

then:

MCC27 and MCC28

CPC29 must be within 00000

CPC29

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

CPC29 must be within 00000

CPC29

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

CPC29 must be within 00000

CPC29

MCC28 – MCC23.

MCC28 is non-zero

MCC27 and MCC28

CPC29 must be within 00000

CPC29

MCC24 – MCC23

are both zero

0430

CPC30 is out of range. When CPC03-B14 = 1, a non-zero entry for CPC30 must be within
TCC45

CPC30

TCC46

0431

CPC31 is out of range. If non-zero, CPC31 must be within TCC41

CPC31

TCC42

Advertising