4–48

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 21

MCC27 is zero and

OPC62 must be within OPC61 < OPC62

MCC28 – MCC23.

MCC28 is non-zero

MCC27 and MCC28

OPC62 must be within OPC61 < OPC62

MCC24 – MCC23

are both zero

0503

Your selection to bridge the First Clamp Open Profile directly into Second Clamp Open Profile,
and set-output upon conclusion of Second Clamp Open Profile (OPC03-B08 = 0 and
OPC03-B09 = 1) is invalid because QDC module does not have a valid SOC (SYS16-B01 = 0).

0504

You have selected closed-loop Press/Pos execution for the First Clamp Open Profile by
OPC04-B01 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC mod-
ule does not have access to a connected clamp pressure transducer.

0507

Your selection to bridge the first two Clamp Open Profiles directly into the Third Clamp Open
Profile, and set-output upon conclusion of the Third Clamp Open Profile (OPC03-B08 = 0,
OPC03-B09 = 0, and OPC03-B10 = 1) is invalid because the QDC module does not have a valid
TOC on-board (SYS16-B02 = 0).

0508

You have selected closed-loop Press/Pos execution for the Second Clamp Open Profile by
OPC04-B03 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC mod-
ule does not have access to a connected clamp pressure transducer.

0511

Your selection to bridge the Second Clamp Open Profile directly into the Third Clamp Open
Profile, and set-output upon conclusion of the Third Clamp Open Profile (OPC03-B09 = 0, and
OPC03-B10 = 1) is invalid because the QDC module does not have a valid TOC on-board
(SYS16-B02 = 0).

0512

You have selected closed-loop Press/Pos execution for the Third Clamp Open Profile by
OPC04-B05 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC mod-
ule does not have access to a connected clamp pressure transducer.

0516

You have selected closed-loop Press/Pos execution for the Clamp Open Slow Profile by
OPC04-B07 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC mod-
ule does not have access to a connected clamp pressure transducer.

0600

Your entire Clamp Open Profile Command Block has been rejected because the QDC module
does not have a valid Clamp Open Slow Configuration Block on-board (SYS16-B03 = 0).

0609

Your OPC09 must be zero because FOC is invalid (SYS16-B00 = 0).

0610

Your OPC10 must be zero because FOC is invalid (SYS16-B00 = 0).

0611

Your OPC11 must be zero because FOC is invalid (SYS16-B00 = 0).

0612

Your OPC12 must be zero because FOC is invalid (SYS16-B00 = 0).

0613

Your OPC13 must be zero because FOC is invalid (SYS16-B00 = 0).

0614

Your OPC14 must be zero because FOC is invalid (SYS16-B00 = 0).

0615

Your OPC15 must be zero because FOC is invalid (SYS16-B00 = 0).

0616

Your OPC16 must be zero because FOC is invalid (SYS16-B00 = 0).

0617

Your OPC17 must be zero because FOC is invalid (SYS16-B00 = 0).

0618

Your OPC18 must be zero because SOC is invalid (SYS16-B01 = 0).

0619

Your OPC19 must be zero because SOC is invalid (SYS16-B01 = 0).

0620

Your OPC20 must be zero because SOC is invalid (SYS16-B01 = 0).

0621

Your OPC21 must be zero because SOC is invalid (SYS16-B01 = 0).

0622

Your OPC22 must be zero because SOC is invalid (SYS16-B01 = 0).

0623

Your OPC23 must be zero because SOC is invalid (SYS16-B01 = 0).

0624

Your OPC24 must be zero because SOC is invalid (SYS16-B01 = 0).

0625

Your OPC25 must be zero because SOC is invalid (SYS16-B01 = 0).

0626

Your OPC26 must be zero because SOC is invalid (SYS16-B01 = 0).

0627

Your OPC27 must be zero because TOC is invalid (SYS16-B02 = 0).

0628

Your OPC28 must be zero because TOC is invalid (SYS16-B02 = 0).

0629

Your OPC29 must be zero because TOC is invalid (SYS16-B02 = 0).

0630

Your OPC30 must be zero because TOC is invalid (SYS16-B02 = 0).

0631

Your OPC31 must be zero because TOC is invalid (SYS16-B02 = 0).

0632

Your OPC32 must be zero because TOC is invalid (SYS16-B02 = 0).