2–107

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

TOC

Velocity Control Limits

Word

Description

TCC45

Velocity Minimum Control Limit [08] Minimum controllable clamp velocity attainable during any Vel/Pos Third Clamp Close Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in TCC47.

TCC46

Velocity Maximum Control Limit [08] Maximum controllable clamp velocity attainable during any Vel/Pos Third Clamp Close Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in TCC48.

TCC47

Selected Velocity Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected velocity valve
during any Vel/Pos Third Clamp Close Profile. The module expects a velocity equal to TCC45 when setting the selected velocity
valve to this %-output during profile execution. The Vel/Pos Third Clamp Close Profile will be executed as a reverse-acting algorithm
if this entry is greater than TCC48.

TCC48

Selected Velocity Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected velocity
valve during any Vel/Pos Third Clamp Close Profile. The module expects a velocity equal to TCC46 when setting the selected veloc-
ity valve to this %-output during profile execution. The Vel/Pos Third Clamp Close Profile will be executed as a reverse-acting algo-
rithm if this entry is less than TCC47.

Profile Tuning Constants

Word

Description

TCC49

Proportional Gain for Pressure Control [30]

TCC50

Integral Gain for Pressure Control [27] or [28]

TCC51

Derivative Gain for Pressure Control [26] or [21]

TCC52

Proportional Gain for Velocity Control [28]

TCC53

Feed Forward Gain for Velocity Control [30]

TCC54 - 56

Open

Profile Pressure Alarm Setpoint

Word

Description

TCC57

Profile High Pressure Alarm Setpoint [02] The module compares real-time clamp pressure against this entry when executing the
Third Clamp CloseProfile. The module sets alarm status bit SYS05-B14 when clamp pressure equals or exceeds this entry during
the Third Clamp Close Profile. A zero entry inhibits SYS05-B14.

TCC58 - 64

Open

Bit-mapped Control Words

Word

Bit

Description

TOC01

Block ID = 00010011 (Low byte). High byte reserved for the module. Do not use.

TOC02

Configuration Selections

B00-B02

Selected Velocity Control Valve
The module uses its algorithm to drive the following output during any Vel/Pos Third Clamp Open Profile.
B02 B01 B00
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8

TOC02

B03

Open

TOC – Third Clamp Open
Configuration Block