Id = 13 – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 254

Advertising
background image

4–30

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 12

0810

HPC10 must be 00000 when HPC11 = 00000.

0812

HPC12 must be 00000 when HPC14 = 00000.

0813

HPC13 must be 00000 when HPC14 = 00000.

0815

HPC15 must be 00000 when HPC17 = 00000.

0816

HPC16 must be 00000 when HPC17 = 00000.

0818

HPC18 must be 00000 when HPC20 = 00000.

0819

HPC19 must be 00000 when HPC20 = 00000.

0821

HPC21 must be 00000 when HPC23 = 00000.

0822

HPC22 must be 00000 when HPC23 = 00000.

0829

HPC29 must be 00000 when HPC31 = 00000.

0830

HPC30 must be 00000 when HPC31 = 00000.

0832

HPC32 must be 00000 when HPC34 = 00000.

0833

HPC33 must be 00000 when HPC34 = 00000.

0835

HPC35 must be 00000 when HPC37 = 00000.

0836

HPC36 must be 00000 when HPC37 = 00000.

0838

HPC38 must be 00000 when HPC40 = 00000.

0839

HPC39 must be 00000 when HPC40 = 00000.

ID = 13

PRC – Pre-Decompression Configuration Block

Error Code

Description

ID = 13

0208

PRC08 is out of range. Valid range is 00000

≤

PRC08

≤

09999

0209

PRC09 is out of range. Valid range is 00000

≤

PRC09

≤

09999

0210

PRC10 is out of range. Valid range is 00000

≤

PRC10

≤

09999

0211

PRC11 is out of range. Valid range is 00000

≤

PRC11

≤

09999

0212

PRC12 is out of range. Valid range is 00000

≤

PRC12

≤

09999

0213

PRC13 is out of range. Valid range is 00000

≤

PRC13

≤

09999

0214

PRC14 is out of range. Valid range is 00000

≤

PRC14

≤

09999

0215

PRC15 is out of range. Valid range is 00000

≤

PRC15

≤

09999

0216

PRC16 is out of range. Valid range is 00000

≤

PRC16

≤

09999

0217

PRC17 is out of range. Valid range is 00000

≤

PRC17

≤

09999

0218

PRC18 is out of range. Valid range is 00000

≤

PRC18

≤

09999

0219

PRC19 is out of range. Valid range is 00000

≤

PRC19

≤

09999

0220

PRC20 is out of range. Valid range is 00000

≤

PRC20

≤

09999

0221

PRC21 is out of range. Valid range is 00000

≤

PRC21

≤

09999

0222

PRC22 is out of range. Valid range is 00000

≤

PRC22

≤

09999

0223

PRC23 is out of range. Valid range is 00000

≤

PRC23

≤

09999

0224

PRC24 is out of range. Valid range is 00000

≤

PRC24

≤

09999

0225

PRC25 is out of range. Valid range is 00000

≤

PRC25

≤

09999

0226

PRC25 is out of range. Valid range is 00000

≤

PRC26

≤

09999

0227

PRC27 is out of range. Valid range is 00000

≤

PRC27

≤

09999

0228

PRC28 is out of range. Valid range is 00000

≤

PRC28

≤

09999

0229

PRC29 is out of range. Valid range is 00000

≤

PRC29

≤

09999

0230

PRC30 is out of range. Valid range is 00000

≤

PRC30

≤

09999

0231

PRC31 is out of range. Valid range is 00000

≤

PRC31

≤

09999

0232

PRC32 is out of range. Valid range is 00000

≤

PRC32

≤

09999

Advertising