Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 23

0228

ERC28 is out of range. Valid range is 00000

≤

ERC28

≤

09999

0229

ERC29 is out of range. Valid range is 00000

≤

ERC29

≤

09999

0230

ERC30 is out of range. Valid range is 00000

≤

ERC30

≤

09999

0231

ERC31 is out of range. Valid range is 00000

≤

ERC31

≤

09999

0232

ERC32 is out of range. Valid range is 00000

≤

ERC32

≤

09999

0233

ERC33 is out of range. Valid range is 00000

≤

ERC33

≤

09999

0234

ERC34 is out of range. Valid range is 00000

≤

ERC34

≤

09999

0235

ERC35 is out of range. Valid range is 00000

≤

ERC35

≤

09999

0236

ERC36 is out of range. Valid range is 00000

≤

ERC36

≤

09999

0237

ERC37 is out of range. Valid range is 00000

≤

ERC37

≤

09999

0238

ERC38 is out of range. Valid range is 00000

≤

ERC38

≤

09999

0239

ERC39 is out of range. Valid range is 00000

≤

ERC39

≤

09999

0240

ERC40 is out of range. Valid range is 00000

≤

ERC40

≤

09999

0243

ERC43 is out of range. Valid range is 00000

≤

ERC43

≤

09999

0244

ERC44 is out of range. Valid range is 00000

≤

ERC44

≤

09999

0247

ERC47 is out of range. Valid range is 00000

≤

ERC47

≤

09999

0248

ERC48 is out of range. Valid range is 00000

≤

ERC48

≤

09999

0249

ERC49 is out of range. Valid range is 00000

≤

ERC49

≤

09999

0250

ERC50 is out of range. Valid range is 00000

≤

ERC50

≤

09999

0251

ERC51 is out of range. Valid range is 00000

≤

ERC51

≤

09999

0252

ERC52 is out of range. Valid range is 00000

≤

ERC52

≤

09999

0253

ERC53 is out of range. Valid range is 00000

≤

ERC53

≤

09999

0343

ERC43 is equal to ERC44. They must not be equal.

0347

ERC47 is equal to ERC48. They must not be equal.

0441

ERC41 is out of range. Valid range is 00000

≤

ERC41 < ERC42

0442

ERC42 is out of range. Valid range is ERC41 < ERC42

≤

09999

0445

ERC45 is out of range. Valid range is 00000

≤

ERC45 < ERC46

0446

ERC46 is out of range. Valid range is ERC45 < ERC46

≤

09999

0502

Your bit pattern in ERC02-B02, ERC02-B01, and ERC02-B00 indicates a selected ejector
velocity control valve that is unconnected according to your entries in MCC02 and MCC04.

0506

Your bit pattern in ERC02-B06, ERC02-B05, and ERC02-B04 indicates a selected ejector
pressure control valve that is unconnected according to your entries in MCC02 and MCC04.

ID = 24

EPC – Ejector Profile Block

Error Code

Description

ID = 24

0209

EPC09 is out of range.
When EPC03-B14 = 0, EPC09 must be within 00000

≤

EPC09

≤

09999

0212

EPC12 is out of range.
When EPC03-B14 = 0, EPC12 must be within 00000

≤

EPC12

≤

09999

0215

EPC15 is out of range.
When EPC03-B14 = 0, EPC15 must be within 00000

≤

EPC15

≤

09999

0221

EPC21 is out of range.
When EPC03-B14 = 0, EPC21 must be within 00000

≤

EPC21

≤

09999

0227

EPC27 is out of range.
When EPC03-B14 = 0, EPC27 must be within 00000

≤

EPC27

≤

09999

0233

EPC33 is out of range.
When EPC03-B14 = 0, EPC33 must be within 00000

≤

EPC33

≤

09999