3–41

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

SYS

Word

Bit

Description

SYS17

Status of Last Successful Decode

The module latches one of the bits in SYS17 and SYS18 (while unlatching all others) when it successfully decodes the
referenced command block and places the new data into operational memory. The module does not latch any bit asso-
ciated with an unrecognizable command block. Set no more than one bit at a time in SYS17 and SYS18.

When this bit
is latched ON:

last successful decode was:

B00

MCC

B01

JCC

B02

FCC

B03

SCC

B04

TCC

B05

LPC

B06

CPC

B07

INC

B08

IPC

B09

PKC

B10

HDC

B11

HPC

B12

PRC

B13

PLC

B14

PPC

B15

PSC

SYS18

Status of Last Successful Decode

The module latches one of the bits in SYS17 and SYS18 (while unlatching all others) when it successfully decodes the
referenced command block and places the new data into operational memory. The module does not latch any bit asso-
ciated with an unrecognizable command block. Set no more than one bit at a time in SYS17 and SYS18.

When this bit
is latched ON:

last successful
decode was:

B00

FOC

B01

SOC

B02

TOC

B03

OSC

B04

OPC

B05

EAC

B06

ERC

When this bit
is latched ON:

last successful
decode was:

B07

EPC

B08

DYC

B09

RLC

B10

CLC

B11

PTC

B12-B15

Open