3–41
Status Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
SYS
Word
Bit
Description
SYS17
Status of Last Successful Decode
The module latches one of the bits in SYS17 and SYS18 (while unlatching all others) when it successfully decodes the
referenced command block and places the new data into operational memory. The module does not latch any bit asso-
ciated with an unrecognizable command block. Set no more than one bit at a time in SYS17 and SYS18.
When this bit
is latched ON:
last successful decode was:
B00
MCC
B01
JCC
B02
FCC
B03
SCC
B04
TCC
B05
LPC
B06
CPC
B07
INC
B08
IPC
B09
PKC
B10
HDC
B11
HPC
B12
PRC
B13
PLC
B14
PPC
B15
PSC
SYS18
Status of Last Successful Decode
The module latches one of the bits in SYS17 and SYS18 (while unlatching all others) when it successfully decodes the
referenced command block and places the new data into operational memory. The module does not latch any bit asso-
ciated with an unrecognizable command block. Set no more than one bit at a time in SYS17 and SYS18.
When this bit
is latched ON:
last successful
decode was:
B00
FOC
B01
SOC
B02
TOC
B03
OSC
B04
OPC
B05
EAC
B06
ERC
When this bit
is latched ON:
last successful
decode was:
B07
EPC
B08
DYC
B09
RLC
B10
CLC
B11
PTC
B12-B15
Open