2–9

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

CPC

Word

Bit

Description

B11

Mold Protection Zone Overrun Selection
= 0 Start Clamp Low Pressure Close Profile on Mold Protection Zone Overrun
= 1 Stop and Zero Outputs on Mold Protection Zone Overrun
During any of the first three Clamp Close Profiles,
if B11 is:

then the module:

clamp position reaches a value immediately terminates the ongoing Clamp Close Profile and checks this bit
less than or equal to CPC61
RESET

immediately begins the Clamp Low Pressure Close Profile

SET

sets its outputs to zero

B12-B13

Open

B14

Velocity Units Selection
= 0 Velocity Parameters in Percent Velocity
= 1 Velocity Parameters in in.(mm)/s
if B14 is: then the module:
RESET

returns all segment velocity actuals (and assumes all velocity setpoints) in units of percent velocity where
FCC46, SCC46, and TCC46 represent 100% velocity

SET

returns all velocity actuals (and assumes all velocity setpoints) in units of in.(mm)/s

B15

Open

CPC04

Configuration Selections

Open/Closed Loop Selection

B00

= 0 Vel/Pos First Clamp Close Profiles Closed Loop
= 1 Vel/Pos First Clamp Close Profiles Open Loop

B01

= 0 Press/Pos First Clamp Close Profiles Closed Loop
= 1 Press/Pos First Clamp Close Profiles Open Loop

B02

= 0 Vel/Pos Second Clamp Close Profiles Closed Loop
= 1 Vel/Pos Second Clamp Close Profiles Open Loop

B03

= 0 Press/Pos Second Clamp Close Profiles Closed Loop
= 1 Press/Pos Second Clamp Close Profiles Open Loop

B04

= 0 Vel/Pos Third Clamp Close Profiles Closed Loop
= 1 Vel/Pos Third Clamp Close Profiles Open Loop

B05

= 0 Press/Pos Third Clamp Close Profiles Closed Loop
= 1 Press/Pos Third Clamp Close Profiles Open Loop

B06

Open

B07

= 0 Clamp Low Pressure Close Profiles Closed Loop
= 1 Clamp Low Pressure Close Profiles Open Loop

ERC Enabled/Disabled Selection

B08

= 0 Vel/Pos First Clamp Close Profiles ERC On
= 1 Vel/Pos First Clamp Close Profiles ERC Off

B09

= 0 Press/Pos First Clamp Close Profiles ERC On
= 1 Press/Pos First Clamp Close Profiles ERC Off

B10

= 0 Vel/Pos Second Clamp Close Profiles ERC On
= 1 Vel/Pos Second Clamp Close Profiles ERC Off

B11

= 0 Press/Pos Second Clamp Close Profiles ERC On
= 1 Press/Pos Second Clamp Close Profiles ERC Off

B12

= 0 Vel/Pos Third Clamp Close Profiles ERC On
= 1 Vel/Pos Third Clamp Close Profiles ERC Off

B13

= 0 Press/Pos Third Clamp Close Profiles ERC ON
= 1 Press/Pos Third Clamp Close Profiles ERC Off

B14

Open

B15

= 0 Clamp Low Pressure Close Profiles ERC On
= 1 Clamp Low Pressure Close Profiles ERC Off

CPC05 - 08

Open