2–100

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Pressure Control Limits

Word

Description

SCC41

Pressure Minimum Control Limit [02] Minimum controllable clamp pressure attainable during any Press/Pos Second Clamp Close
Profile. The module expects this clamp pressure when setting its selected pressure valve to the %-output in SCC43.

SCC42

Pressure Maximum Control Limit [02] Maximum controllable clamp pressure attainable during any Press/Pos Second Clamp Close
Profile. The module expects this clamp pressure when setting its selected pressure valve to the %-output in SCC44.

SCC43

Selected Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pressure
valve during anyPress/Pos Second Clamp Close Profile. The module expects a pressure equal to SCC41 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Second Clamp Close Profile will be executed as a reverse-
acting algorithm if this entry is greater than SCC44.

SCC44

Selected Pressure Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos Second Clamp Close Profile. The module expects a pressure equal to SCC42 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Second Clamp Close Profile will be executed as a reverse-
acting algorithm if this entry is less than SCC43.

Velocity Control Limits

Word

Description

SCC45

Velocity Minimum Control Limit [08] Minimum controllable clamp velocity attainable during any Vel/Pos Second Clamp Close Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in SCC47.

SCC46

Velocity Maximum Control Limit [08] Maximum controllable clamp velocity attainable during any Vel/Pos Second Clamp Close
Profile. The module expects this clamp velocity when setting its selected velocity valve to the %-output in SCC48.

SCC47

Selected Velocity Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected velocity valve
during anyVel/Pos Second Clamp Close Profile. The module expects a velocity equal to SCC45 when setting the selected velocity
valve to this %-output during profile execution. The Vel/Pos Second Clamp Close Profile will be executed as a reverse-acting algo-
rithm if this entry is greater than SCC48.

SCC48

Selected Velocity Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected velocity
valve during any Vel/Pos Second Clamp Close Profile. The module expects a velocity equal to SCC46 when setting the selected
velocity valve to this %-output during profile execution. The Vel/Pos Second Clamp Close Profile will be executed as a reverse-act-
ing algorithm if this entry is less than SCC47.

Profile Tuning Constants

Word

Description

SCC49

Proportional Gain for Pressure Control [30]

SCC50

Integral Gain for Pressure Control [27] or [28]

SCC51

Derivative Gain for Pressure Control [26] or [21]

SCC52

Proportional Gain for Velocity Control [28]

SCC53

Feed Forward Gain for Velocity Control [30]

SCC54 - 56

Open

Profile Pressure Alarm Setpoint

Word

Description

SCC57

Profile High Pressure Alarm Setpoint [02] The module compares real-time clamp pressure against this entry when executing the
Second Clamp Close Profile. The module sets alarm status bit SYS05-B13 when clamp pressure equals or exceeds this entry
during the Second Clamp Close Profile. A zero entry inhibits SYS05-B13.

SCC58 - 64

Open