2–19

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

DYC

Word

Bit

Description

DYC02

B10

If clamp position is less than OPC61 and
all within each group are true:

then the module:

– OPC11 is not zero
– clamp position less than non-zero entry in OPC11, OPC14, or OPC17

terminates any action in progress (except ongoing
Ejector Profile) and starts First Clamp Open Profile

– OPC11 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC11, OPC14, and OPC17

–OPC03-B08 is SET

terminates any action in progress (except ongoing
Ejector Profile) and sets outputs to FOC33 - FOC40

– OPC11 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC11, OPC14, and OPC17

– OPC03-B08 is RESET
– OPC20 is not zero
– clamp position less than non-zero entry in OPC20, OPC23, or OPC26

terminates any action in progress (except ongoing
Ejector Profile) and starts Second Clamp Open
Profile

– OPC11 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC11,OPC14, and OPC17

– OPC03-B08 is RESET
– OPC20 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC20, OPC23, and OPC26

– OPC03-B09 is SET

terminates any action in progress (except ongoing
Ejector Profile) and sets outputs to SOC33 - SOC40

– OPC11 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC11, OPC14, and OPC17

– OPC03-B08 is RESET
– OPC20 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC20, OPC23, and OPC26

– OPC03-B09 is RESET
– OPC29 is not zero
– clamp position exceeds non-zero entry in OPC29, OPC32, or OPC35

terminates any action in progress (except ongoing
Ejector Profile) and starts Third Clamp Open Profile

– OPC11 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC11,OPC14, and OPC17

– OPC03-B08 is RESET
– OPC20 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC20, OPC23, and OPC26

– OPC03-B09 is RESET
– OPC29 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC29, OPC32, and OPC35

– OPC03-B10 is SET

terminates any action in progress (except ongoing
Ejector Profile) and sets outputs to TOC33 - TOC40

– OPC11 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC11, OPC14, and OPC17

– OPC03-B08 is RESET
– OPC20 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC20, OPC23, and OPC26

– OPC03-B09 is RESET
– OPC29 is zero or is not zero when clamp position exceeds all

non-zero entries in OPC29, OPC32, and OPC35

– OPC03-B10 is RESET
Also occurs for clamp position less than OPC62 but not less than OPC61.

terminates any action in progress (except ongoing
Ejector Profile) and starts Clamp Open Slow Profile

clamp position equals or exceeds OPC62

terminates any action in progress (except ongoing
Ejector Profile) and sets outputs to OSC33 - OSC40