4.8 Detailed iQpump Parameter Descriptions

This section explains the basic settings required for initial drive operation. Checking these basic parameter settings will help

to ensure a successful drive start-up.

Refer to Parameter List on page 227

for a complete listing of drive parameters if more

information is required for parameters not listed in this section.

Parameter

Name

Page

A1-01

Access Level Selection

119

A1-03

Initialize Parameters

120

b1-01

Frequency Reference Selection 1

121

b1-02

Run Command Selection 1

124

b1-03

Stopping Method Selection

125

b3-01

Speed Search Selection at Start

127

b5-01

PID Function Setting

127

b5-03

Integral Time Setting (I)

128

b5-09

PID Output Level Selection

128

b5-39

PID Setpoint Display Digits

128

C1-01 to

C1-04

Accel, Decel Times 1 and 2

128

E2-01

Motor Rated Current

129

E2-04

Number of Motor Poles

129

H1-01 to

H1-07

Functions for Terminals S1 to S7

129

H2-01 to

H2-03

Terminal MA/MB/MC, P1/PC, and P2/PC

Function Selection

140

H3-01

Terminal A1 Signal Level Selection

149

H3-02

Terminal A1 Function Selection

149

H3-03,

H3-04

Terminal A1 Gain and Bias Settings

149

H3-09

Terminal A2 Signal Level Selection

150

H3-10

Terminal A2 Function Selection

150

H3-11,

H3-12

Terminal A2 Gain and Bias Setting

150

H4-01

Multi-Function Analog Terminal AM Monitor

Selection

151

H4-02,

H4-03

Multi-Function Analog Output Terminal AM

Gain/Bias

151

L5-01

Number of Auto Restart Attempts

151

L5-04

Fault Reset Interval Time

152

o1-08

Third Line User Monitor Selection

152

P1-01

Pump Mode

152

Parameter

Name

Page

P1-02

System Units

152

P1-03

Feedback Device Scaling

153

P1-04

Start / Draw Down Level

153

P1-05

Start Level Delay Time

153

P1-06

Minimum Pump Speed

153

P1-08

Low Feedback Level

153

P1-09

Low Feedback Level Fault Delay Time

153

P1-10

Low Feedback Selection

154

P1-11

High Feedback Level

154

P1-12

High Feedback Level Fault Delay Time

154

P1-13

High Feedback Selection

154

P2-01

Sleep Level Type

155

P2-02

Sleep Level

155

P2-03

Sleep Delay Time

155

P4-01

Pre-Charge Level

155

P4-02

Pre-Charge Frequency

155

P4-03

Pre-Charge Time

156

P4-05

Pre-Charge Loss of Prime Level

159

P4-06

Pre-Charge Frequency 2

159

P4-07

Pre-Charge Time 2

159

P4-08

Pre-Charge Loss of Prime Level 2

159

P4-10

AUTO Mode Operator Run Power Down

Storage

159

P4-11

Thrust Bearing Acceleration Time

159

P4-12

Thrust Bearing Frequency

159

P4-13

Thrust Bearing Deceleration Time

160

P4-17

Utility Start Delay

160

P4-32

Pre-Charge Level 2

160

P5-02

HAND Reference 1

161

P5-04

HAND Key Function Selection

161

Q1-01

PID Controller Setpoint 1

161

n

A1-01: Access Level Selection

Allows or restricts access to drive parameters.

No.

Parameter Name

Setting Range

Default

A1-01

Access Level Selection

0 to 3

2

Setting 0: Operation only

Access to only parameters A1-01, A1-04, and all U monitor parameters.

Setting 1: User Parameters

Access to only a specific list of parameters set to A2-01 through A2-32. These User Parameters can be accessed using the

Setup Mode of the digital operator.

Setting 2: Advanced Access Level (A) and Setup Access Level (S)

All parameters can be viewed and edited.

4.8 Detailed iQpump Parameter Descriptions

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual

119

4

Start-Up Programming & Operation

Advertising