A.1 Power Ratings

u

Single-Phase 200 V Class Drives

Table A.1 Single-Phase 200 V Class Power Ratings

Item

Specification

Single-Phase Drive Model

<1>

BV0006

BV0010

BV0012

BV0018

Maximum Motor Size Allowed kW (HP)

<2>

1.1 (1)

2.2 (3)

3.0 (3)

3.7 (5)

Input

Input Current (A)

<3>

13.8

20.2

24.0

35.0

Output

Rated Output Capacity (kVA)

<4>

2.3

3.7

4.6

6.7

Output Current (A)

6.0

9.6

12.0

17.5

Overload Tolerance

120% of rated output current for 1 minute

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User-adjustable 2 to 15 kHz

Max Output Voltage (V)

Single-phase power: 200 to 240 V

(both proportional to input voltage)

Max Output Frequency (Hz)

400 Hz (user-adjustable)

Power Supply

Rated Voltage

Rated Frequency

Single-phase power: 200 to 240 V 50/60 Hz

DC power supply: 270 to 340 V

<5>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency Fluctuation

±5%

Harmonic Corrective

Actions

DC Link Choke

Optional

<1> Drives with single-phase power supply input will output three-phase power and cannot run a single-phase motor.
<2> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor rated current.

<3> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<4> Rated motor capacity is calculated with a rated output voltage of 230 V.
<5> DC is not available for UL standards.