Three-phase 400 v class drives – Yaskawa iQpump Micro User Manual

Page 220

Advertising
background image

u

Three-Phase 400 V Class Drives

Table A.4 Three-Phase 400 V Class Power Ratings

Item

Specification

Three-Phase Model

4V0002

4V0004

4V0005

4V0007

4V0009

Maximum Applicable Motor Capacity kW (HP)

<1>

0.75 (1.0)

1.5 (2)

2.2 (3)

3.0 (3)

3.7 (5)

Input

Input Current (A)

<2>

2.1

4.3

5.9

8.1

9.4

Output

Rated Output Capacity (kVA)

<3>

1.6

3.1

4.1

5.3

6.7

Output Current (A)

2.1

4.1

5.4

6.9

8.8

Overload Tolerance

120% of rated output current for 60 s

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User-adjustable 2 to 15 kHz

Max Output Voltage (V)

Three-phase power: 380 to 480 V (proportional to input voltage)

Max Output Frequency (Hz)

400 Hz (user-adjustable)

Power Supply

Rated Voltage

Rated Frequency

Three-phase power: 380 to 480 V 50/60 Hz

DC power supply: 510 to 680 V

<4>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency

Fluctuation

±5%

Harmonic Corrective

Actions

DC Link Choke

Optional

<1> The motor capacity (HP) refers to a NEC 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the

motor rated current.

<2> Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 460 V.
<4> DC is not available for UL standards.

Table A.5 Three-Phase 400 V Class Power Ratings Continued

Item

Specification

Three-Phase Model

4V0011

4V0018

4V0023

4V0031

4V0038

Maximum Applicable Motor Capacity kW (HP)

<1>

5.5 (7.5)

7.5 (10)

11 (15)

15 (20)

18.5 (25)

Input

Input Current (A)

<2>

14.0

20.0

24.0

38.0

44.0

Output

Rated Output Capacity (kVA)

<3>

8.5

13.3

17.5

23.6

29.0

Output Current (A)

11.1

17.5

23.0

31.0

38.0

Overload Tolerance

120% of rated output current for 60 s

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User-adjustable 2 to 15 kHz

Max Output Voltage (V)

Three-phase power: 380 to 480 V (proportional to input voltage)

Max Output Frequency (Hz)

400 Hz (user-adjustable)

Power Supply

Rated Voltage

Rated Frequency

Three-phase power: 380 to 480 V 50/60 Hz

DC power supply: 510 to 680 V

<4>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency Fluctuation

±5%

Harmonic Corrective

Actions

DC Link Choke

Optional

<1> The motor capacity (HP) refers to a NEC 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the

motor rated current.

<2> Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 460 V.
<4> DC is not available for UL standards.

A.1 Power Ratings