B6: dwell function – Yaskawa iQpump Micro User Manual

Page 233

Advertising
background image

u

b6: Dwell Function

No.

(Addr.

Hex)

Name

Description

Values

Page

b6-01

(01B6) Dwell Reference at Start Dwell Ref @Start

Parameters b6-01 and b6-02 set the frequency to hold and the

time to maintain that frequency at start.

Default: 0.0 Hz

Min.: 0.0

Max.: 400.0

b6-02

(01B7) Dwell Time at Start

Dwell Time @Start

Default: 0.0 s

Min.: 0.0

Max.: 10.0

b6-03

(01B8) Dwell Reference at Stop Dwell Ref @Stop

Parameters b6-03 and b6-04 set the frequency to hold and the

time to maintain that frequency at stop.

Default: 0.0 Hz

Min.: 0.0

Max.: 400.0

b6-04

(01B9) Dwell Time at Stop

Dwell Time @Stop

Default: 0.0 s

Min.: 0.0

Max.: 10.0