B.14 T: Motor Tuning

Enter data into the following parameters to tune the motor and drive for optimal performance

u

T1: Induction Motor Auto-Tuning

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

T1-01

(0701)

Auto-Tuning Mode

Selection

Tuning Mode Sel

2: Term Resistance

2: Stationary Auto-Tuning for Line-to-Line Resistance

Default: 2

Range: 2

T1-02

(0702)

Motor Rated Power

Mtr Rated Power

Sets the motor rated power as specified on the motor nameplate.

Note:

Use the following formula to convert horsepower

into kilowatts:

1HP = 0.746 kW.

Default:

<1>

Min.: 0.03 kW

Max.: 650.00

kW

T1-04

(0704)

Motor Rated Current

Rated Current

Sets the motor rated current as specified on the motor

nameplate.

Default:

<1>

Min.: 10% of

drive rated

current

Max.: 200% of

drive rated

current

<1> Default setting is dependent on parameter o2-04, Drive Model Selection.