Reattaching the Protective Covers

Pass power wiring and control signal wiring through the exit holes on the bottom of the conduit bracket of the drive. Place

power wiring and control signal wiring in separate conduits. Properly connect all wiring after installing the drive and connecting

other devices. Reattach all protective covers when wiring is complete.

A

A –Pass power wiring and control signal wiring through different exit holes at the

bottom of the drive.

Figure 3.9 Reattach the Protective Covers and Conduit Bracket on an IP20/NEMA Type 1 Drive

u

IP20/NEMA Type 1 Top Cover Removal and Installation

To improve the ambient temperature rating of a NEMA Type 1 drive from 40 °C to 50 °C or to mount NEMA Type 1 drives

side-by-side, the top cover can be removed. Remove the top cover and set L8-35 to 2.

Note:

Removing the top cover of a NEMA Type 1 drive converts the drive to an IP20/Open-Chassis rating, and the drive will no longer have a

NEMA Type 1 rating.

n

Removing the Top Cover

Insert the blade of a straight-edge screwdriver into the opening of the top cover. Gently lift up on the front cover as indicated

by the arrow in

Figure 3.10

to remove it from the drive.

Figure 3.10 Removing the Top Cover

n

Reattaching the Top Cover

Align the connection tabs on the underside of the top cover with the connection tabs on the drive. Pinch in on the top cover

to click the cover into place on the drive.

Connection tabs

Figure 3.11 Reattaching the Top Cover