Three-phase 200 v class drives – Yaskawa iQpump Micro User Manual

Page 219

Advertising
background image

u

Three-Phase 200 V Class Drives

Table A.2 Three-Phase 200 V Class Power Ratings

Item

Specification

Three-Phase Drive Model

2V0006

2V0010

2V0012

2V0020

Maximum Motor Size Allowed kW (HP)

<1>

1.1 (1.5)

2.2 (3)

3.0 (3)

5.5 (5)

Input

Input Current (A)

<2>

7.3

10.8

13.9

24.0

Output

Rated Output Capacity (kVA)

<3>

2.3

3.7

4.6

7.5

Output Current (A)

6.0

9.6

12.0

19.6

Overload Tolerance

120% of rated output current for 1 minute

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User-adjustable 2 to 15 kHz

Max Output Voltage (V)

Three-phase power: 200 to 240 V

(proportional to input voltage)

Max Output Frequency (Hz)

400 Hz (user-adjustable)

Power Supply

Rated Voltage

Rated Frequency

Three-phase power: 200 to 240 V 50/60 Hz

DC power supply: 270 to 340 V

<4>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency

Fluctuation

±5%

Harmonic Corrective

Actions

DC Link Choke

Optional

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor rated current.

<2> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 230 V.
<4> DC is not available for UL standards.

Table A.3 Three-Phase 200 V Class Power Ratings Continued

Item

Specification

Three-Phase Model

2V0030

2V0040

2V0056

2V0069

Maximum Motor Size Allowed kW (HP)

<1>

7.5 (10)

11 (10)

15 (20)

18.5 (25)

Input

Input Current (A)

<2>

37.0

52.0

68.0

80.0

Output

Rated Output Capacity (kVA)

<3>

11.4

15.2

21.3

26.3

Output Current (A)

30.0

40.0

56.0

69.0

Overload Tolerance

120% of rated output current for 1 minute

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User-adjustable 2 to 15 kHz

Max Output Voltage (V)

Three-phase power: 200 to 240 V

(proportional to input voltage)

Max Output Frequency (Hz)

400 Hz (user-adjustable)

Power Supply

Rated Voltage

Rated Frequency

Three-phase power: 200 to 240 V 50/60 Hz

DC power supply: 270 to 340 V

<4>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency

Fluctuation

±5%

Harmonic Corrective

Actions

DC Link Choke

Optional

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor rated current.

<2> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 230 V.
<4> DC is not available for UL standards.