5.1 Drive Faults, Alarms, Errors, and Messages

u

Types of Faults, Alarms, and Errors

Check the drive digital operator for information about possible faults if the drive or motor fails to operate.
If problems occur that are not covered in this manual, contact the nearest Yaskawa representative with the following

information:
• Drive model
• Software version
• Date of purchase
• Description of the problem
• List of modified parameters.

Table 5.1

contains descriptions of the various types of alarms, faults, and errors that may occur while operating the drive.

Table 5.1 Types of Faults, Alarms, and Errors

Type

Drive Response

Page

Faults

When the drive detects a fault:
• The digital operator or optional HOA keypad displays text indicating the specific fault and the ALM indicator

LED remains lit until the fault is reset.

• The fault interrupts drive output and the motor coasts to a stop.
• Some faults allow the user to select the stopping method when the fault occurs.
• If a digital output is programmed for fault output (H2-oo = E), it will close if a fault occurs.
The drive will remain inoperable until the fault is cleared.

Refer to Fault Reset Methods on page 198

for details.

165

Minor Faults and

Alarms

When the drive detects an alarm or a minor fault:
• The digital operator/HOA keypad displays text indicating the specific alarm or minor fault, and the ALM indicator

LED flashes.

• The drive continues running the motor, although some alarms allow the user to select a stopping method when

the alarm occurs.

• A multi-function contact output set to be tripped by a minor fault (H2- oo = 10) closes. If the output is set to

be tripped by an alarm, the contact will not close.

• The digital operator/HOA keypad displays text indicating a specific alarm and the ALM indicator LED flashes.
Remove the cause of the problem to reset a minor fault or alarm.

180

Operator

Programming

Errors

An Operator Programming error occurs when parameter settings conflict or do not match hardware settings (such

as with an option card).

When the drive detects an Operator Programming error:
• The digital operator/HOA keypad displays text indicating the specific error.
• Multi-function contact outputs do not operate.
The drive will not operate the motor until the error has been reset. Correct the settings that caused the error.

192

Copy Function

Errors

Copy Function Errors occur when using the optional HOA keypad or the USB Copy Unit to copy, read, or verify

parameter settings.
• The HOA keypad displays text indicating the specific error.
• Multi-function contact outputs do not operate.
Pressing any key on the keypad will clear the fault. Investigate the cause of the problem (such as model

incompatibility) and try again.

195

Digital Operator

Display Messages

The drive will display messages on the LED operator or optional HOA keypad to indicate temporary drive statuses

during normal pump operation. Messages do not require any action from the user and will clear from the display

automatically.