1 mechanical installation – Yaskawa iQpump Micro User Manual

Page 53

Advertising
background image

Table 2.3 Dimensions for IP20/NEMA Type 1 Enclosure Drives

H6

4-M4

W1

W

H5

H2

H4

H

H3

D1

D

H1

t1

Voltage

Class

Drive Model

Dimensions mm (in)

W

H

D

<1>

W1

H1

H2

H3

H4

H5

H6

D1

t1

Wt.

kg (lb.)

Single-

Phase

200 V Class

BV0006F

108

(4.25)

149.5

(5.89)

137.5

(5.41)

96

(3.78)

128

(5.03)

118

(4.65)

4

(0.16)

20

(0.79)

5

(0.20)

1.5

(0.06)

58

(2.28)

5

(0.20)

1.9

(4.2)

BV0010F

108

(4.25)

149.5

(5.89)

154

(6.06)

96

(3.78)

128

(5.03)

118

(4.65)

4

(0.16)

20

(0.79)

5

(0.20)

1.5

(0.06)

58

(2.28)

5

(0.20)

2.0

(4.4)

BV0012F

140

(5.51)

153

(6.02)

163

(6.42)

128

(5.04)

128

(5.03)

118

(4.65)

4.8

(0.19)

20

(0.79)

5

(0.20)

5

(0.20)

65

(2.56)

5

(0.20)

2.6

(5.7)

BV0018F

170

(6.69)

171

(6.73)

180

(7.08)

158

(6.22)

133

(5.23)

118

(4.64)

4.8

(0.19)

38

(1.50)

5

(0.20)

5

(0.20)

65

(2.56)

5

(0.20)

3.3

7.3

Three-

Phase

200 V Class

2V0010F

108

(4.25)

149.5

(5.89)

129

(5.08)

96

(3.78)

128

(5.03)

118

(4.65)

4

(0.16)

20

(0.79)

5

(0.20)

1.5

(0.06)

58

(2.28)

5

(0.20)

1.9

(4.2)

2V0012F

108

(4.25)

149.5

(5.89)

137.5

(5.41)

96

(3.78)

128

(5.03)

118

(4.65)

4

(0.16)

20

(0.79)

5

(0.20)

1.5

(0.06)

58

(2.28)

5

(0.20)

1.9

(4.2)

2V0020F

140

(5.51)

153

(6.02)

143

(5.63)

128

(5.04)

128

(5.03)

118

(4.65)

4.8

(0.19)

20

(0.79)

5

(0.20)

5

(0.20)

65

(2.56)

5

(0.20)

2.6

(5.7)

Three-

Phase

400 V Class

4V0002F

108

(4.25)

149.5

(5.89)

99

(3.90)

96

(3.78)

128

(5.03)

118

(4.65)

4

(0.16)

20

(0.79)

5

(0.20)

1.5

(0.06)

28

(1.10)

5

(0.20)

1.4

(3.1)

4V0004F

108

(4.25)

149.5

(5.89)

137.5

(5.41)

96

(3.78)

128

(5.03)

118

(4.65)

4

(0.16)

20

(0.79)

5

(0.20)

1.5

(0.06)

58

(2.28)

5

(0.20)

1.9

(4.2)

4V0005F

108

(4.25)

149.5

(5.89)

154

(6.06)

96

(3.78)

128

(5.03)

118

(4.65)

4

(0.16)

20

(0.79)

5

(0.20)

1.5

(0.06)

58

(2.28)

5

(0.20)

1.9

(4.2)

4V0007F

108

(4.25)

149.5

(5.89)

154

(6.06)

96

(3.78)

128

(5.03)

118

(4.65)

4

(0.16)

20

(0.79)

5

(0.20)

1.5

(0.06)

58

(2.28)

5

(0.20)

1.9

(4.2)

4V0009F

108

(4.25)

149.5

(5.89)

154

(6.06)

96

(3.78)

128

(5.03)

118

(4.65)

4

(0.16)

20

(0.79)

5

(0.20)

1.5

(0.06)

58

(2.28)

5

(0.20)

1.9

(4.2)

4V0011F

140

(5.51)

153

(6.02)

143

(5.63)

128

(5.04)

128

(5.03)

118

(4.65)

4.8

(0.19)

20

(0.79)

5

(0.20)

5

(0.20)

65

(2.56)

5

(0.20)

2.6

(5.7)

<1> The installed 24 V power supply option adds 27 mm (1.06 in.) to the total depth of the drive.