Refer to factory recommended branch circuit, For proper input fuse or circuit breaker sizing – Yaskawa iQpump Micro User Manual

Page 295

Advertising
background image

Drive

Model

Terminal

Recomm.

Gauge

AWG, kcmil

Wire Range
AWG, kcmil

Screw

Size

Tightening

Torque

N•m (lb.in.)

4V0018

R/L1, S/L2, T/L3

10

14 to 6

M4

2.1 to 2.3

(18.6 to 20.4)

U/T1, V/T2, W/T3

10

14 to 6

⊖, ⊕1, ⊕2

14 to 6

B1, B2

14 to 10

8

14 to 6

M5

2 to 2.5

(17.7 to 22.1)

4V0023

R/L1, S/L2, T/L3

10

10 to 6

M4

2.1 to 2.3

(18.6 to 20.4)

U/T1, V/T2, W/T3

10

10 to 6

⊖, ⊕1, ⊕2

10 to 6

B1, B2

14 to 10

8

10 to 6

M5

2 to 2.5

(17.7 to 22.1)

4V0031

R/L1, S/L2, T/L3

8

10 to 6

M5

3.6 to 4.0

(31.8 to 35.4)

U/T1, V/T2, W/T3

8

10 to 6

⊖, ⊕1, ⊕2

10 to 6

B1, B2

14 to 10

2.7 to 3.0

(23.9 to 26.6)

6

10 to 6

M6

5.4 to 6.0

(47.8 to 53.1)

4V0038

R/L1, S/L2, T/L3

6

10 to 6

M5

3.6 to 4.0

(31.8 to 35.4)

U/T1, V/T2, W/T3

8

10 to 6

⊖, ⊕1, ⊕2

10 to 6

B1, B2

10 to 8

2.7 to 3.0

(23.9 to 26.6)

6

10 to 6

M6

5.4 to 6.0

(47.8 to 53.1)

n

Factory Recommended Branch Circuit Protection for UL Compliance

Yaskawa recommends installing one of the following types of branch circuit protection to maintain compliance with UL508C.

Semiconductor protective type fuses are preferred.
Branch circuit protection shall be provided by any of the following according to

Table C.5

.

• Non-time Delay Class J, T, or CC fuses.
• Time Delay Class J, T, CC, or RK5 fuses.
• Semiconductor fuses.
• Molded Case Circuit Breakers (MCCB).

Table C.5 Factory Recommended Drive Branch Circuit Protection

Drive Model

Non-time Delay

Fuse Rating (A)

<1>

Time Delay Fuses

Bussmann

Semiconductor

Fuse Part Number
(Fuse Ampere)

<4>

MCCB

<5>

Class J, T, or CC

Fuse Rating (A)

<2>

Class RK5

Fuse Rating (A)

<3>

Rating (A)

Minimum

Enclosure

Volume (in

3

)

200 V Class Single-Phase Drives

BV0006

40

20

30

FWH-80B (80)

30

1152

BV0010

40

35

45

FWH-100B (100)

50

1152

BV0012

50

40

50

FWH-125B (125)

60

1152

BV0018

80

60

70

FWH-175B (175)

80

1152

200 V Class Three-Phase Drives

2V0006

20

10

15

FWH-25A14F (25)

15

1152

2V0010

25

15

20

FWH-70B (70)

25

1152

2V0012

25

20

30

FWH-70B (70)

30

1152

2V0020

40

40

50

FWH-90B (90)

60

1152

2V0030

60

80

FWH-100B (100)

90

1152