D2: frequency upper/lower limits, D3: jump frequency – Yaskawa iQpump Micro User Manual

Page 237

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

d1-14

(028F) Frequency Reference 14 Reference 14

Frequency reference when digital inputs "Multi-Step Speed

Reference 1, 3, 4" (H1-oo = 3, 5, 32) are on.

Default: 0.00 Hz

Min.: 0.00
Max.: 400.00

<1>

d1-15

(0290)

Frequency Reference 15 Reference 15

Frequency reference when digital inputs "Multi-Step Speed

Reference 2, 3, 4" (H1-oo = 4, 5, 32) are on.

Default: 0.00 Hz

Min.: 0.00
Max.: 400.00

<1>

d1-16

(0291)

Frequency Reference 16 Reference 16

Frequency reference when digital inputs "Multi-Step Speed

Reference 1, 2, 3, 4" (H1-oo = 3, 4, 5, 32) are on.

Default: 0.00 Hz

Min.: 0.00
Max.: 400.00

<1>

d1-17

(0292)

Jog Frequency

Reference

Jog Reference

Frequency reference when digital inputs "Jog Frequency

Reference", "Forward Jog", or "Reverse Jog." are on. "Jog

Frequency Reference" has priority over "Multi-Step Speed

Reference 1 to 16”.

Default: 6.00 Hz

Min.: 0.00
Max.: 400.00

<1>

<1> Range upper limit is determined by parameters d2-01, Frequency Reference Upper Limit, and E1-04, Maximum Output Frequency.

u

d2: Frequency Upper/Lower Limits

No.

(Addr.

Hex.)

Name

LCD Display

Description

Setting

Page

d2-01

(0289)

Frequency Reference

Upper Limit

Ref Upper Limit

Sets the frequency reference upper limit as a percentage of the

maximum output frequency.

Default: 100.0%

Min.: 0.0

Max.: 110.0

d2-02

(028A)

Frequency Reference

Lower Limit

Ref Lower Limit

Sets the frequency reference lower limit as a percentage of the

maximum output frequency.

Default: 0.0%

Min.: 0.0

Max.: 110.0

d2-03

(0293)

Master Speed Reference

Lower Limit

Ref1 Lower Limit

Sets the lower limit for frequency references from analog inputs

as a percentage of the maximum output frequency.

Default: 0.0%

Min.: 0.0

Max.: 110.0

u

d3: Jump Frequency

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

d3-01

(0294)

Jump Frequency 1

Jump Freq 1

Eliminates problems with resonant vibration of the motor/

machine by avoiding continuous operation in predefined

frequency ranges. The drive accelerates and decelerates the

motor through the prohibited frequency ranges.

Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.

Setting this parameter to 0.0 disables the function.

Default: 0.0 Hz

Min.: 0.0

Max.: 400.0

d3-02

(0295)

Jump Frequency 2

Jump Freq 2

Default: 0.0 Hz

Min.: 0.0

Max.: 400.0

d3-03

(0296)

Jump Frequency 3

Jump Freq 3

Default: 0.0 Hz

Min.: 0.0

Max.: 400.0

d3-04

(0297)

Jump Frequency Width Jump Bandwidth

Sets the dead-band width around each selected prohibited

frequency reference point.

Default: 1.0 Hz

Min.: 0.0

Max.: 20.0

B.4 d: References

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual

237

B

Parameter List

Advertising
This manual is related to the following products: