U1 - 19 – Yaskawa iQpump Micro User Manual

Page 280

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Analog

Output Level

Unit

U1-19

(0066)

MEMOBUS/Modbus

Error Code

Transmit Err

Displays the contents of a MEMOBUS/Modbus error.

U1 - 19=

00000000

CRC Error
Data Length Error
Not Used

Parity Error
Overrun Error
Framing Error

Timed Out

Not Used

1

1

0

1

1

1

1

0

CRC Error

Data Length Error

Not Used

Parity Error

Overrun Error

Framing Error

Timed Out

Not Used

No signal output

available

U1-24

(007D) Input Pulse Monitor

Term RP Inp Freq

Displays the frequency to pulse train input terminal RP.

Determined by

H6-02

1 Hz

U1-25

(004D)

Software Number

(Flash)

CPU 1 SW Number

FLASH ID

No signal output

available

U1-26

(005B) Software No. (ROM)

CPU 2 SW Number

ROM ID

No signal output

available

U1-75

(0851)

Time-Hour/Minute

Time Hr Min HHMM Displays the current time (Hours and Minutes).

No signal output

available

U1-76

(0852)

Date – Year

Date Year

Displays the current year.

No signal output

available

U1-77

(0853)

Date – Month/Day

Date Mo Day MMDD Displays the current date (Month and Date).

No signal output

available

U1-78

(0854)

Date – Week Day

Date Week

Displays the current day of the week.

0: Sunday

1: Monday

2: Tuesday

3: Wednesday

4: Thursday

5: Friday

6: Saturday

No signal output

available

U1-90

(0BA5) Pump Setpoint

Pump Setpoint

Displays the PID Setpoint.

No signal output

available

dep. on

P1-02

U1-91

(0BA6) Pump Feedback

Pump Feedback

Displays the PID Feedback.

No signal output

available

dep. on

P1-02

U1-93

(0BA8)

Total Setpoint

Compensation

Total SP Comp.

Displays the total absolute Setpoint Compensation.

No signal output

available

dep. on

P1-02

U1-94

(0BA9) Motor Speed

Motor Speed

Displays the absolute value of the output frequency (U1-02)

converted to RPM.

No signal output

available

1 RPM

U1-99

(0BAE) Anti-No-Flow Timer

ANF Timer

The Anti-No-Flow reduces the output frequency when this

value reaches the P2-24 setting.

No signal output

available

0.1 s

<1> Display is in the following units:

BV0006 to BV0018, 2V0006 to 2V0040, and 4V0002 to 4V0023: 0.01 A units.
2V0056 to 2V0069 and 4V0031 to 4V0038: 0.1 A units.

<2> When reading the value of this monitor via MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current.
<3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives.
<4> This value has two decimal places (0.01 kW) if the drive is set for a maximum applicable motor capacity up to and including 11 kW, and one

decimal place (0.1 kW) if the maximum applicable motor capacity is higher than 11 kW.

B.15 U: Monitors

280

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual