B.5 E: Motor Parameters

u

E1: V/f Pattern

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

E1-01

(0300)

Input Voltage Setting

Input Voltage

This parameter must be set to the power supply voltage.

WARNING! Electrical Shock Hazard. Drive input voltage

(not motor voltage) must be set in E1-01 for the protective

features of the drive to function properly. Failure to do so

may result in equipment damage and/or death or personal

injury.

Default: 230 V

<1>

Min.: 155
Max.: 255

<1>

E1-03

(0302)

V/f Pattern Selection

V/F Selection

0: 50 Hz

1: 60 Hz Saturation

2: 60 Hz Saturation

3: 72 Hz

4: 50 Hz VT1

5: 50 Hz VT2

6: 60 Hz VT1

7: 60 Hz VT2

8: 50 Hz HST1

9: 50 Hz HST2

A: 60 Hz HST1

B: 60 Hz HST2

C: 90 Hz

D: 120 Hz

E: 180 Hz

F: Custom V/F

0: 50 Hz, Constant torque 1

1: 60 Hz, Constant torque 2

2: 60 Hz, Constant torque 3 (50 Hz base)

3: 72 Hz, Constant torque 4 (60 Hz base)

4: 50 Hz, Variable torque 1

5: 50 Hz, Variable torque 2

6: 60 Hz, Variable torque 3

7: 60 Hz, Variable torque 4

8: 50 Hz, High starting torque 1

9: 50 Hz, High starting torque 2

A: 60 Hz, High starting torque 3

B: 60 Hz, High starting torque 4

C: 90 Hz (60 Hz base)

D: 120 Hz (60 Hz base)

E: 180 Hz (60 Hz base)

F: Custom V/f, E1-04 through E1-13 settings define the V/f

pattern

Default: F

<2>

Range: 0 to 9;

A to FF

B.5 E: Motor Parameters

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual

239