Three-phase 400 v class – Yaskawa iQpump Micro User Manual

Page 294

Advertising
background image

Drive

Model

Terminal

Recomm.

Gauge

AWG, kcmil

Wire Range
AWG, kcmil

Screw

Size

Tightening

Torque

N•m (lb.in.)

2V0030

R/L1, S/L2, T/L3

8

10 to 6

M4

2.1 to 2.3

(18.6 to 20.4)

U/T1, V/T2, W/T3

8

10 to 6

⊖, ⊕1, ⊕2

10 to 6

B1, B2

14 to 10

8

10 to 6

M5

2 to 2.5

(17.7 to 22.1)

2V0040

R/L1, S/L2, T/L3

6

10 to 6

M4

2.1 to 2.3

(18.6 to 20.4)

U/T1, V/T2, W/T3

8

10 to 6

⊖, ⊕1, ⊕2

10 to 6

B1, B2

14 to 10

6

10 to 6

M5

2 to 2.5

(17.7 to 22.1)

2V0056

R/L1, S/L2, T/L3

4

6 to 4

M6

5.4 to 6.0

(47.8 to 53.1)

U/T1, V/T2, W/T3

4

6 to 4

⊖, ⊕1, ⊕2

6 to 4

B1, B2

10 to 6

M5

2.7 to 3.0

(23.9 to 26.6)

6

8 to 4

M6

5.4 to 6.0

(47.8 to 53.1)

2V0069

R/L1, S/L2, T/L3

3

8 to 2

M8

9.9 to 11

(87.6 to 97.4)

U/T1, V/T2, W/T3

3

8 to 2

⊖, ⊕1, ⊕2

8 to 2

B1, B2

8 to 6

M5

2.7 to 3.0

(23.9 to 26.6)

6

6 to 4

M6

5.4 to 6.0

(47.8 to 53.1)

n

Three-Phase 400 V Class

Table C.4 Wire Gauge and Torque Specifications

Drive

Model

Terminal

Recomm.

Gauge

AWG, kcmil

Wire Range
AWG, kcmil

Screw

Size

Tightening

Torque

N•m (lb.in.)

4V0002

4V0004

R/L1, S/L2, T/L3

14

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

14

14 to 10

4V0005

4V0007

4V0009

R/L1, S/L2, T/L3

14

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

10

14 to 10

4V0011

R/L1, S/L2, T/L3

12

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

10

14 to 10

C.1 UL Standards