Yaskawa iQpump Micro User Manual

Page 166

Advertising
background image

Digital Operator Display

Fault Name

Cause

Possible Solution

Control circuit is damaged

• Cycle power to the drive.
• If the problem continues, replace the drive.

Control circuit terminals have shorted out

(+V, AC).

• Check for wiring errors along the control circuit terminals.
• Correct the wiring.
Check the resistance of the speed potentiometer and related wiring.

Control terminal input current has

exceeded allowable levels.

• Check the input current.
• Reduce the current input to control circuit terminal (+V) to 20 mA.

Digital Operator Display

Fault Name

CPF03

PWM Data Error
There is a problem with the PWM data.

Cause

Possible Solution

Hardware is damaged

Replace the drive.

Digital Operator Display

Fault Name

CPF06

EEPROM Memory Data Error
Error in the data saved to EEPROM

Cause

Possible Solution

There is an error in EEPROM control

circuit

• Turn off the power and check the connection between the control board and the drive.
• If the problem continues, replace the drive.

The power supply was switched off while

parameters were being saved to the drive

Reinitialize the drive (A1-03 = 2220, 3330).

Digital Operator Display

Fault Name

CPF07

Terminal Board Communications Error
A communication error occurred at the terminal board.

Cause

Possible Solution

There is a faulty connection between the

terminal board and the control board

Turn off the power and reconnect the control circuit terminals.

Digital Operator Display

Fault Name

CPF08

EEPROM Serial Communication Fault
EEPROM communications are not functioning properly.

Cause

Possible Solution

Terminal board or control board is not

connected properly.

Turn the power off and check the control terminal connections.

There is a faulty connection between the

terminal board and the control board

Turn off the power and reconnect the control circuit terminals.

Digital Operator Display

Fault Name

CPF11

RAM Fault

Cause

Possible Solution

Hardware is damaged

Replace the drive.

Digital Operator Display

Fault Name

CPF12

FLASH Memory Fault
Problem with the ROM (FLASH memory).

Cause

Possible Solution

Hardware is damaged

Replace the drive.

Digital Operator Display

Fault Name

CPF13

Watchdog Circuit Exception
Self-diagnostics problem.

Cause

Possible Solution

5.2 Fault Detection

166

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual

Advertising
This manual is related to the following products: