Yaskawa iQpump Micro User Manual

Page 241

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

E2-04

(0311)

Number of Motor Poles Number of Poles

Sets the number of motor poles. Automatically set during

Auto-Tuning.

Default: 2

Min.: 2

Max.: 48

129

E2-05

(0312)

Motor Line-to-Line

Resistance

Term Resistance

Sets the phase-to-phase motor resistance. Automatically set

during Auto-Tuning.

Default:

<1>

Min.: 0.000 Ω

Max.: 65.000 Ω

E2-06

(0313)

Motor Leakage

Inductance

Leak Inductance

Sets the voltage drop due to motor leakage inductance as a

percentage of motor rated voltage. Automatically set during

Auto-Tuning.

Default:

<1>

Min.: 0.0%

Max.: 40.0%

E2-10

(0317)

Motor Iron Loss for

Torque Compensation

Motor Iron Loss

Sets the motor iron loss.

Default:

<1>

Min.: 0 W

Max.: 65535 W

E2-11

(0318)

Motor Rated Power

Mtr Rated Power

Sets the motor rated power in kilowatts (1 HP = 0.746 kW).

Automatically set during Auto-Tuning.

Default:

<1>

Min.: 0.00 kW

Max.: 650.00

kW

<1> Default setting is dependent on parameter o2-04, Drive Model Selection.
<2> Display is in the following units:

BV0006 to BV0018, 2V0006 to 2V0040, and 4V0002 to 4V0023: 0.01 A units.
2V0056 to 2V0069 and 4V0031 to 4V0038: 0.1 A units.

B.5 E: Motor Parameters

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual