3.9 Wiring Checklist

No.

Item

Page

Drive, peripherals, option cards

1

Check drive model number to ensure receipt of correct model.

46

2

Check for correct braking resistors, DC link chokes, noise filters, and other peripheral devices.

–

Installation area and physical setup

3

Ensure area surrounding the drive complies with specifications.

50

Power supply voltage, output voltage

4

The voltage from the power supply should fall within the input voltage specification range of the drive.

–

5

The voltage rating for the motor should match the drive output specifications.

46

Main circuit wiring

6

Confirm proper branch circuit protection exists per National and Local codes.

60

7

Properly wire the power supply to drive terminals R/L1, S/L2 and T/L3.

–

8

Properly wire the drive and motor together.

The motor lines and drive output terminals R/T1, V/T2 and W/T3 should match in order to produce the desired

phase order. If the phase order is incorrect, the drive will rotate in the opposite direction.

73

9

Use 600 Vac vinyl-sheathed wire for the power supply and motor lines.

70

10

Use the correct wire gauges for the main circuit. Refer to

Table 3.4

,

Table 3.5

, or

Table 3.6

.

70

When using comparatively long motor cable, calculate the amount of voltage drop.

3 x voltage resistance (Ω/km) x cable length (m) x motor rated current (A) x 10

-3

Motor rated voltage (V) x 0.02 ≥

70

If the cable between the drive and motor exceeds 50 m, adjust the carrier frequency (C6-02) accordingly.

73

11

Properly ground the drive.

73

12

Tightly fasten all terminal screws. Refer to

Table 3.4

,

Table 3.5

, or

Table 3.6

.

70

13

Set up overload protection circuits when running multiple motors from a single drive.

M1

OL1

OL2

OLn

MC1

MC2

MCn

M2

Mn

Drive

MC1 - MCn
OL 1 - OL n

... magnetic contactor
... thermal relay

Power supply

Note: Close MC1 through MCn before operating the drive.

–

14

If using a braking resistor or dynamic braking resistor unit, install a magnetic contactor. Properly install the resistor,

and ensure that overload protection shuts off the power supply.

–

15

Verify phase advancing capacitors are NOT installed on the output side of the drive.

–

Control circuit wiring

16

Use twisted-pair cables for all drive control circuit wiring.

–

17

Ground the shields of shielded wiring to the GND terminal.

77

18

If using a 3-Wire sequence, set parameters for MFDI terminals S1 through S7, and properly wire control circuits.

62

19

Check for any other wiring mistakes. Only use a multimeter to check wiring.

–

20

Properly fasten the control circuit terminal screws in the drive. Refer to

Table 3.4

,

Table 3.5

, or

Table 3.6

.

70

21

Pick up all wire clippings.

–

22

Ensure that no frayed wires on the terminal block are touching other terminals or connections.

–

23

Properly separate control circuit wiring and main circuit wiring.

–

24

Analog signal line wiring should not exceed 50 m.

–

25

Safe Disable Input wiring should not exceed 30 m.

–

3.9 Wiring Checklist

82

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual

Advertising