Yaskawa Yasnac PC NC User Manual

Page 175

Advertising
background image

YASNAC PC NC Operating Manual

Chapter 4: Maintenance

4 - 17

(3) Jog Operation is Impossible

(a) Jog mode signal is not input

Check the bit status of I/O monitor #3000.

Dl = l

Other bits (DO, D2 to D7) = O

(b) Axis move direction signal is not input.

Check the bit status of I/O monitor #3071 and #3072.

(c) Jog feedrate signal is not input, or job feedrate setting parameter is incorrect

Check the bit status on the I/O monitor screen whether it changes according to the opera-
tion of the JOG FEEDF.ATE switch, and also check if the setting for the parameters is
correct.

#3071

#3072

D0

+1st axis

D0

-1st axis

Dl

+2nd axis

Dl

-2nd axis

D2

+3rd axis

D2

-3rd axis

D3

+4th axis

D3

-4th axis

D4 +5th

axis

D4 -5th

axis

Advertising