Yaskawa Yasnac PC NC User Manual
Page 175
Advertising
YASNAC PC NC Operating Manual
Chapter 4: Maintenance
4 - 17
(3) Jog Operation is Impossible
(a) Jog mode signal is not input
Check the bit status of I/O monitor #3000.
Dl = l
Other bits (DO, D2 to D7) = O
(b) Axis move direction signal is not input.
Check the bit status of I/O monitor #3071 and #3072.
(c) Jog feedrate signal is not input, or job feedrate setting parameter is incorrect
Check the bit status on the I/O monitor screen whether it changes according to the opera-
tion of the JOG FEEDF.ATE switch, and also check if the setting for the parameters is
correct.
#3071
#3072
D0
+1st axis
D0
-1st axis
Dl
+2nd axis
Dl
-2nd axis
D2
+3rd axis
D2
-3rd axis
D3
+4th axis
D3
-4th axis
D4 +5th
axis
D4 -5th
axis