2) Stored Stroke Limit B, C (G22, G23) *
The area either outside or inside the boundary set by parameters or by the commands in a
program is established as the entry prohibited area. The boundary is set with the coordinate
values in the machine coordinate system. Whether the entry prohibited area is established out-
side or inside the boundary can be determined by the setting for a parameter. The function is
made valid upon completion of the reference point return after turning ON the power.
Fig. 1.2.3.2
Stored Stroke Limit B Function
•
In addition to the stored stroke limits A and B, stored stroke limit C can be added.
•
With the stored stroke limit C, set the boundary of the area and inside or outside the
boundary by parameters.
•
According to the setting for the parameter or the input signal, one of the stored stroke limit
C (third to fifth prohibited area) can be made valid.
•
For details of the stored stroke limit B, C, refer to 4.2.3 “Stored Stroke Limit B and C
(G22, G23)” in the PROGRAMMING MANUAL.
G CODE
FUNCTION
GROUP
G22
Turning ON the stored stroke limit B
04
G23
Turning OFF the stored stroke limit B