Yaskawa Yasnac PC NC User Manual

Page 20

Advertising
background image

YASNAC PC NC Operating Manual

Chapter 1: Outline of the YASNAC System

1 - 11

(

2) Stored Stroke Limit B, C (G22, G23) *

The area either outside or inside the boundary set by parameters or by the commands in a
program is established as the entry prohibited area. The boundary is set with the coordinate
values in the machine coordinate system. Whether the entry prohibited area is established out-
side or inside the boundary can be determined by the setting for a parameter. The function is
made valid upon completion of the reference point return after turning ON the power.

Fig. 1.2.3.2

Stored Stroke Limit B Function

•

In addition to the stored stroke limits A and B, stored stroke limit C can be added.

•

With the stored stroke limit C, set the boundary of the area and inside or outside the
boundary by parameters.

•

According to the setting for the parameter or the input signal, one of the stored stroke limit
C (third to fifth prohibited area) can be made valid.

•

For details of the stored stroke limit B, C, refer to 4.2.3 “Stored Stroke Limit B and C
(G22, G23)” in the PROGRAMMING MANUAL.

G CODE

FUNCTION

GROUP

G22

Turning ON the stored stroke limit B

04

G23

Turning OFF the stored stroke limit B

04

Advertising