4.1.11 Self - Diagnosis Function Specification

While Boot up of PC NC

System Number

Switch

Mode of operation

Operation Mode

Type

0

Normal operation mode

O

1

Normal operation mode

O

2

Normal operation mode

O

4

Ladder development mode

O

E

Memory operation mode

**

Processing

classification

number display

Progress message display

corresponding to the content of NC

power input processing.

LED Display

System

number SW

Cause of failure

4

3

2

1

1

LED PORT WRITE

O

O

O

0, 1, 2, 4, E

JCP20 PCB

2

YENET RAM CHECK

O

O

O

0, 1, 2, 4, E

JCP20 PCB

3

SYSTEM-SW READ

O

O

O

0, 1, 2, 4, E

JCP20 PCB

4

FLASH TOTAL CHECK

O

O

O

0, 1, 2

JCP20 PCB

5

JIF PORT READ

O

O

O

0, 1, 2, 4, E

JCP20 PCB

6

REV.READ

O

O

O

0, 1, 2, 4, E

JCP20 PCB

7

ISA-RAM CHECK

O

O

O

0, 1, 2, 4, E

JCP20 PCB

8

YENET INITIAL

O

O

0, 1, 2, 4, E

JCP20 PCB

9

CMOS CLEAR

O

O

0, 1, 2, 4,

JCP20 PCB

10

CMOS TOTAL CHECK

O

O

0, 1, 2,

JCP20 PCB

11

PARAMETER READ

O

O

O

0, 1, 2, 4,

JCP20 PCB

12

MOTION INITIAL

O

0, 1, 2, 4,

JCP20 PCB, SERVO

13

LADDER START

O

0, 1, 2, 4

JCP20 PCB

14

INTEX INITIAL

O

O

O

0, 1, 2, 4, E

15

TASK SETUP

O

O

0, 1, 2, 4, E

16

JTABLE SET

O

O

0, 1, 2, 4, E

JCP20 PCB