Yaskawa Yasnac PC NC User Manual

Page 211

Advertising
background image

YASNAC PC NC Operating Manual

Appendix 2: Alarm Tables

A2 - 7

alarm.397

During tape/direct operation, operation interruption that does not allow the re-execution has been carried out.

alarm.400

An O number of five or more digits is designated.

alarm.401

An N number of five or more digits is designated.

alarm.402

A P number of five or more digits is designated.

alarm.406

Before the axis move, the axis is in the stored stroke limit No. 2 area.

alarm.407

Before the axis move, the axis is in the stored stroke limit No. 3 area.

alarm.408

Before the axis move, the axis is in the stored stroke limit No. 4 area.

alarm.409

Before the axis move, the axis is in the stored stroke limit No. 5 area.

alarm.411

Reference point return has not been completed (X-axis).

alarm.412

Reference point return has not been completed (Y-axis).

alarm.413

Reference point return has not been completed (Z-axis).

alarm.414

Reference point return has not been completed (4th-axis).

alarm.415

Reference point return has not been completed (5th-axis).

alarm.421

After the execution of G27, the axis has not returned to the reference point (X-axis).

alarm.422

After the execution of G27, the axis has not returned to the reference point (Y-axis).

alarm.423

After the execution of G27, the axis has not returned to the reference point (Z-axis).

alarm.424

After the execution of G27, the axis has not returned to the reference point (4th-axis).

alarm.425

After the execution of G27, the axis has not returned to the reference point (5th-axis).

alarm.431

Before the axis move, the axis has reached the entry prohibited area (outside) of stored stroke limit (X-axis)

alarm.432

Before the axis move, the axis has reached the entry prohibited area (outside) of stored stroke limit (Y-axis)

alarm.433

Before the axis move, the axis has reached the entry prohibited area (outside) of stored stroke limit (Z-axis)

alarm.434

Before the axis move, the axis has reached the entry prohibited area (outside) of stored stroke limit (4th-axis)

alarm.435

Before the axis move, the axis has reached the entry prohibited area (outside) of stored stroke limit (5th-axis)

alarm.480

The cylindrical interpolation command error has occurred.

alarm.481

A command error has occurred in the cylindrical interpolation mode.

alarm.482

The polar coordinate interpolation command error has occurred.

alarm.483

A command error has occurred in the polar coordinate interpolation mode.

alarm.484

Program interrupt has occurred in the cylindrical or polar coordinate interpolation mode.

alarm.491

In the G31 block, skip signal (1) has not been input.

alarm.492

In the G31 block, skip signal (2) has not been input.

alarm.494

When G31 is executed, the skip signal (1) is not ready.

alarm.495

When G31 is executed, the skip signal (2) is not ready.

alarm.1000

DNC time-out error has occurred.

Alarm No.

Description

Advertising