YASNAC PC NC Operating Manual

Appendix 2: Alarm Tables

A2 - 10

alarm.2053

When the separately installed PG is used for reference point return, the deceleration LS is turned from OFF to
ON before the C-phase is latched (Z-axis).

alarm.2054

When the separately installed PG is used for reference point return, the deceleration LS is turned from OFF to
ON before the C-phase is latched (4th-axis).

alarm.2055

When the separately installed PG is used for reference point return, the deceleration LS is turned from OFF to
ON before the C-phase is latched (5th-axis).

alarm.2060

The reference point return (low-speed type) is executed in the manual skip B (measuring) mode.

alarm.2061

Reference point return area error has occurred (X-axis).

alarm.2062

Reference point return area error has occurred (Y-axis).

alarm.2063

Reference point return area error has occurred (Z-axis).

alarm.2064

Reference point return area error has occurred (4th-axis).

alarm.2065

Reference point return area error has occurred (5th-axis).

alarm.2070

After the completion of measurement in the manual skip (A/B) mode, measuring cycle is executed again
without returning the contact detection axis.

alarm.2071

Reference point return position error has occurred (X-axis).

alarm.2072

Reference point return position error has occurred (Y-axis).

alarm.2073

Reference point return position error has occurred (Z-axis).

alarm.2074

Reference point return position error has occurred (4th-axis).

alarm.2075

Reference point return position error has occurred (5th-axis).

alarm.2081

In reference point return, the deceleration LS is turned OFF after it has been turned ON once and then turned
ON again (X-axis).

alarm.2082

In reference point return, the deceleration LS is turned OFF after it has been turned ON once and then turned
ON again (Y-axis).

alarm.2083

In reference point return, the deceleration LS is turned OFF after it has been turned ON once and then turn
ON again (Z-axis).

alarm.2084

In reference point return, the deceleration LS is turned OFF after it has been turned ON once and then turn
again (4th-axis).

alarm.2085

In reference point return, the deceleration LS is turned OFF after it has been turned ON once and then turned
ON again (5th-axis).

alarm.2091

According to the parameter setting, retraction operation must be made in reference point return operation (X-
axis).

alarm.2092

According to the parameter setting, retraction operation must be made in reference point return operation (Y-
axis).

alarm.2093

According to the parameter setting, retraction operation must be made in reference point return operation (Z-
axis).

alarm.2094

According to the parameter setting, retraction operation must be made in reference point return operation
(4th-axis).

alarm.2095

According to the parameter setting, retraction operation must be made in reference point return operation
(5th-axis).

Alarm No.

Description