Hitachi L300P User Manual

Page 106

Advertising
background image

L300P Inverter

Configur

ing Dr

iv

e

P

a

ra

met

e

rs

3–37

For example, you can set B037=01 to have the inverter suppress the displaying of all analog
input parameters when A001=01, as shown in the first row of the following table.

Function

Code

Data

Resulting Non-displayed

Functions (when B37 = 01)

Notes

A001

01

A005, A006, A011 – A016,
A101–A105, A111 – A114,
C081 – C083, C121 – C123

[O], [OI], [O2] terminal
functions

A002

01, 03, 04,

05

B087

Stop key function

A019

00

A028 – A035

Multi-speed function

C001 – C005

02, 03, 04,

05

A044, A244

02

B100 – B113

Control methods

A051

01

A052 – A059

DC braking

A071

01

A072 – A076, C044

PID function

A094

01

A095 – A096

2-stage adjustable frequency

A294

01

A0295 – A296

B013, B213

02

B015 – B020

Electric thermal characteris-
tic

B021

01, 02

B022, B023

Overload restriction

B024

01, 02

B025, B026

Overload restriction 2

B095

01, 02

B090 – B096

Dynamic braking function

C001 – C005

06

A038, A039

Jogging

08

A203, A204, A220, A241 –
A244, A261, A262, A292, A293
– A296, B212, B213, H203,
H204, H206

2nd motor control

11

B088

Free-run stop

18

C102

Reset

27, 28, 29

C101

UP/DWN

A094

01

A131

Select method to switch to
second accel/decel profile

A294

01

A095, A096

Select method to switch to
second accel/decel profile,
2nd motor

A097

01, 02, 03

A131

Acceleration pattern
constant

A098

01, 02, 03

A132

Deceleration pattern
constant

B098

01, 02

B099, C085

Thermistor function

C021, C022,

C026

02, 06

C042, C043

Frequency arrival signal