L300P inverters have a built-in RS485 serial communications interface. This serial communica-
tions function provides a way of controlling from 1 to 32 inverters on a common serial network.
In a typical application, a host computer or controller is the master and each of the inverter(s) is
a slave, as shown in the figure below.

The specifications for L300P Series RS485 serial communications are in the following table:

Item

Specifications

User-selectable

Transmission speed

2400 / 4800 / 9600 / 19200 bps

Communication modes

Half duplex (one device transmits at a time)

Synchronization

Direct current transmission

Character code

ASCII codes

LSB placement

Transmits LBB first

Electrical interface

RS485 differential transceiver

Data bits

7 or 8 bits

Parity

None / even / odd

Stop bits

1 or 2 bits

Start convention

One-way start from host device command

Wait time for response

10 to 1000 ms

Connections

Station address numbers from 1 to 32

Error check

Overrun / Fleming block check code / vertical
or horizontal parity

L300P