Using Keypad Devices

Inverter Front
Panel Keypad

The L300P Series inverter front keypad contains all the elements for both monitoring and
programming parameters. The keypad layout (OPE–SRE) is shown below. All other program-
ming devices for the inverter have a similar key arrangement and function.

Key and
Indicator Legend

Run/Stop LED – ON when the inverter output is ON and the motor is developing torque,

and OFF when the inverter output is OFF (Stop Mode).

Program/Monitor LED – This LED is ON when the inverter is ready for parameter editing

(Program Mode). It is normally OFF when the parameter display is monitoring data
(Monitor Mode). However, the PRG LED will be ON whenever you are monitoring the
value of parameter D001. (When the keypad is enabled as the frequency source via
A001=02, you can edit the inverter frequency directly from D001 monitor display by using
the Up/Down keys.)

Run Key – Press this key to run the motor (the Run Enable LED must be ON first). Parame-

ter F004, Keypad Run Key Routing, determines whether the Run key generates a Run FWD
or Run REV command.

Run Key Enable LED – is ON when the inverter is ready to respond to the Run key, OFF

when the Run key is disabled.

Stop/Reset Key – Press this key to stop the motor when it is running (uses the programmed

deceleration rate). This key will also reset an alarm that has tripped.

Potentiometer – allows an operator to directly set the motor speed when the potentiometer

is enabled for output frequency control

Potentiometer Enable LED – ON when the potentiometer is enabled for value entry.

Parameter Display – a 4-digit, 7-segment display for parameters and function codes.

Display Units: Hertz/Volts/Amperes/kW/% – These LEDs indicate the units associated

with the parameter display. When the display is monitoring a parameter, the appropriate
LED is ON. In the case of kW units, both Volts and Amperes LEDs will be ON. An easy way
to remember this is that kW = (V x A)/1000.

Power LED – This LED is ON when the power input to the inverter is ON.

Alarm LED – This LED is ON when an alarm condition has tripped the inverter. Clearing

the alarm will turn this LED OFF again. See Chapter 6 for details on clearing alarms.

Function Key – This key is used to navigate through the lists of parameters and functions

for setting and monitoring parameter values.

Up/Down ( ,

) Keys – Use these keys to alternately move up or down the lists of

parameter and functions shown in the display, and increment/decrement values.

Store (

) Key – When the unit is in Program Mode and the operator has edited a param-

eter value, press the Store key to write the new value to the EEPROM. This parameter is then
displayed at powerup by default. If you want to change the powerup default, navigate to a
new parameter value and press the Store key.

Run/Stop LED

Program/Monitor LED

Run Key Enable LED

Run Key

Power LED

Alarm LED

Display Units LEDs

Hertz
Volts or Amperes
(kW = both ON)
Percent

Parameter Display

Potentiometer Enable LED

Potentiometer

Stop/Reset Key

Hz

POWER

A

RUN

PRG

RUN

STOP

RESET

MIN

MAX

HITACHI

FUNC

1

2

%

ALARM

STR

V

kW

5 0.0

1

2

STR