3–44

The input logic convention is programmable for each of the six inputs. Most inputs default to
normally open (active high), but you can select normally closed (active low) in order to invert
the sense of the logic.

NOTE: An input terminal configured for option code 18 ([RS] Reset command) cannot be
configured for normally closed operation.

“C” Function

Run

Mode

Edit

Lo Hi

Defaults

Units

SRW Display

Func.

Code

Name

Description

–FE2

(CE)

–FU2

(UL)

–FR

(Jpn)

C011

Terminal [1] active state

Select logic convention, two
option codes:
00 normally openN.O.
01 normally closed N.C.

✘ ✔

00

00

00

>C011 IN-TM

O/C-1 NO

C012

Terminal [2] active state

✘ ✔

00

00

00

>C012 IN-TM

O/C-2 NO

C013

Terminal [3] active state

✘ ✔

00

01

00

>C013 IN-TM

O/C-3 NO

C014

Terminal [4] active state

✘ ✔

00

00

00

>C014 IN-TM

O/C-4 NO

C015

Terminal [5] active state

✘ ✔

00

00

00

>C015 IN-TM

O/C-5 NO

C019

Terminal [FW] active
state

✘ ✔

00

00

00

>C019 IN-TM

O/C-FW NO