Software lock – Hitachi L300P User Manual

Page 154

Advertising
background image

Using Intelligent Input Terminals

Oper

ations

a

nd Moni

tor

ing

4–24

Software Lock

When the terminal [SFT] is turned ON, the data of all the parameters and functions (except the
output frequency, depending on the setting of B031) is locked (prohibited from editing). When
the data is locked, the keypad keys cannot edit inverter parameters. To edit parameters again,
turn OFF the [SFT] terminal input.

Use parameter B031 to select whether the output frequency is excluded from the lock state or is
locked as well.

Opt.

Code

Symbol

Function Name

Input

State

Description

15

SFT

Software Lock

ON

The keypad and remote programming
devices are prevented from changing
parameters

OFF

The parameters may be edited and stored

Valid for
inputs:

C001, C002, C003, C004,
C005

Required
settings:

B031 (excluded from lock)

Notes:
When the [SFT] terminal is turned ON, only

the output frequency can be changed.

Software lock can include the output

frequency by setting B031.

Software lock by the operator is also possible

without the [SFT] terminal being used
(B031).

5

3

1

4

2

FW

TH

PLC

P24

CM1

See I/O specs on page

4–8

.

SFT

Example (requires input configuration—
see page

3–43

):

Advertising