Parameter Settings for Keypad Entry

Appendix C

C–6

Fine Tuning
Functions

A098

Deceleration curve setting

00

00

00

A101

[OI]–[L] input active range start
frequency

0.00

0.00

0.00

A102

[OI]–[L] input active range end
frequency

0.00

60.00

0.00

A103

[OI]–[L] input active range start
current

20.

20.

20.

A104

[OI]–[L] input active range end
current

100.

100.

100.

A105

[OI]–[L] input start frequency
enable

01

01

01

A111

[O2]–[L] input active range start
frequency

0.00

0.00

0.00

A112

[O2]–[L] input active range end
frequency

0.00

0.00

0.00

A113

[O2]–[L] input active range start
voltage

–100.

–100.

–100.

A114

[O2]–[L] input active range end
voltage

100.

100.

100.

A131

Acceleration curve constants setting

02

02

02

A132

Deceleration curve constants setting

02

02

02

“A” Group Parameters

Default Setting

User

Setting

Func.

Code

Name

-FE2 (Europe)

-FU2 (USA)

-FR (Japan)

“B” Group Parameters

Default Setting

User Setting

Func.

Code

Name

-FE2 (Europe)

-FU2 (USA)

-FR (Japan)

B001

Selection of restart mode

00

00

00

B002

Allowable under-voltage power
failure time

1.0

1.0

1.0

B003

Retry wait time before motor restart

1.0

1.0

1.0

B004

Instantaneous power failure / under-
voltage trip alarm enable

00

00

00

B005

Number of restarts on power failure /
under-voltage trip events

00

00

00

B006

Phase loss detection enable

00

00

00

B007

Restart frequency threshold

0.00

0.00

0.00

Advertising