“C” Group: Intelligent Terminal Functions

The five input terminals [1], [2], [3], [4], and [5] can be configured for any of 33 different
functions (34 functions for –xFE2/–xFU2 models). The next two tables show how to configure
the five terminals. The inputs are logical, in that they are either OFF or ON. We define these
states as OFF=0, and ON=1.

The inverter comes with default options for the five terminals. These default settings are
initially unique, each one having its own setting. Note that European and US versions have
different default settings. You can use any option on any terminal.

Input Terminal
Configuration

Functions and Options – The function codes in the following table let you assign one of 33
(or 34) options to any of the five logic inputs for the L300P inverters. The functions C001
through C005 configure the terminals [1] through [5] respectively. The “value” of these partic-
ular parameters is not a scalar value, but it is a discrete number that selects one option from
many available options.

For example, if you set function C001=01, you have assigned option 01 (Reverse Run) to
terminal [1]. The option codes and the specifics of how each one works are in Chapter 4.

“C” Function

Run

Mode

Edit

Lo Hi

Defaults

Units

SRW Display

Func.

Code

Name

Description

–FE2

(CE)

–FU2

(UL)

–FR

(Jpn)

C001

Terminal [1] function

33 programmable

functions

(34 functions for

–xFE2/–xFU2

models) available for

terminals (see next

section)

✘ ✔

18

[RS]

18

[RS]

18

[RS]

>C001 IN-TM

1 RS

C002

Terminal [2] function

✘ ✔

16

[AT]

16

[AT]

16

[AT]

>C002 IN-TM

2 AT

C003

Terminal [3] function

✘ ✔

03

[CF2]

13

[USP]

03

[CF2]

>C003 IN-TM

3 JG

C004

Terminal [4] function

✘ ✔

02

[CF1]

02

[CF1]

02

[CF1]

>C004 IN-TM

4 FRS

C005

Terminal [5] function

✘ ✔

01

[RV]

01

[RV]

01

[RV]

>C005 IN-TM

5 2CH