L300P Inverter

Appendix B

B–5

Communications Protocol

Introduction to
Command List

The network master sends a frame to initiate
communications with a slave, as shown in the
figure to the right. After the set waiting time
(per parameter C078, the inverter responds.

The following table lists the commands, single-character codes sent to a particular device on
the network.

NOTE: Use of command 08 – set inverter parameters to default values first requires setting the
initialization mode parameter B084 to 01 (initializes parameters only) or 02 (initializes param-
eters and clears the trip history).

Command

Code

Description

User-selectable

00

Forward / Reverse / Stop command

✔

01

Setting of frequency in standard profile

✔

02

Setting of intelligent terminal state

✔

03

Read all monitor data (block read)

—

04

Read inverter status

—

05

Read trip history

—

06

Read a single parameter value

—

07

Write a single parameter value

✔

08

Set inverter parameters to default values

✔

09

Verifies that the requested setting can be
written to EEPROM.

—

0A

Writes a parameter value to EEPROM

✔

0B

Requests the recalculation of internal constant

✔

Host

(master)

wait

time

frame

Inverter

(slave)

frame