Hitachi L300P User Manual

Page 85

Advertising
background image

“A” Group: Standard Functions

Configur

ing Dr

iv

e

P

a

ra

meters

3–16

The V/f free-setting endpoint f7/V7
parameters must stay within the more
basic inverter limits in order for the
specified free-setting characteristic
curve to be achieved. For example, the
inverter cannot output a higher voltage
than the input voltage or the AVR
setting voltage (Automatic Voltage
Regulation), set by parameter A082.
The graph to the right shows how the
inverter input voltage would clip (limit)
the characteristic curve if exceeded.

The following table shows the methods of torque control selection.

0

Output voltage

Output

frequency

f6

f7

V6

V7

Hz

(even)

B101 to
B113

(odd)

Voltage to output or AVR voltage

B100 to B112

“A” Function

Run

Mode

Edit

Lo Hi

Defaults

Units

SRW Display

Func.

Code

Name

Description

–FE2

(CE)

–FU2

(UL)

–FR

(Jpn)

A041 Torque boost method

selection

Two options:
00 Manual torque boost
01 Automatic torque boost

✘ ✘

00

00

00

>A041 V-Boost

Mode MANUAL

A241 Torque boost method

selection, 2nd motor

Two options (for 2nd
motor):
00 Manual torque boost
01 Automatic torque boost

✘ ✘

00

00

00

>A241 2V-Boost

Mode MANUAL

A042 Manual torque boost

value

Can boost starting torque
between 0 and 20% above
normal V/f curve, from 0 to
1/2 base frequency

✔ ✔

1.0

1.0

1.0

>A042 V-Boost

Code 01.0%

A242 Manual torque boost

value, 2nd motor

Can boost starting torque
between 0 and 20% above
normal V/f curve, from 0 to
1/2 base frequency

✔ ✔

1.0

1.0

1.0

>A242 2V-Boost

Code 01.0%

A043 Manual torque boost

frequency adjustment

Sets the frequency of the
V/f breakpoint A in graph
(top of previous page) for
torque boost

✔ ✔

5.0

5.0

5.0

%

>A043 V-Boost

F 05.0%

A243 Manual torque boost

frequency adjustment,
2nd motor

Sets the frequency of the
V/f breakpoint A in graph
(top of previous page) for
torque boost

✔ ✔

5.0

5.0

5.0

%

>A243 2V-Boost

F 05.0%

A044 V/f characteristic curve

selection, 1st motor

Three torque control modes:
00 V/f constant torque
01 V/f variable torque
02 V/f free-setting curve

✘ ✘

00

01

00

>A044 Control

1st VC

A244 V/f characteristic curve

selection, 2nd motor

Three torque control modes:
00 V/f constant torque
01 V/f variable torque
02 V/f free-setting curve

✘ ✘

00

01

00

>A244 2Control

2nd VC

A045 V/f gain setting

Sets voltage gain of the
inverter from 20 to 100%

✔ ✔ 100. 100. 100.

%

>A045 V-Gain

Gain 100%