B” group: fine-tuning functions, Automatic restart mode and phase loss, B” group: fine-tuning functions 3–28 – Hitachi L300P User Manual

Page 97

Advertising
background image

“B” Group: Fine-Tuning Functions

Configur

ing Dr

iv

e

P

a

ra

meters

3–28

“B” Group: Fine-Tuning Functions

The “B” Group of functions and parameters adjust some of the more subtle but useful aspects
of motor control and system configuration.

Automatic
Restart Mode and
Phase Loss

The restart mode determines how the inverter will resume operation after a fault causes a trip
event. The four options provide advantages for various situations. Frequency matching allows
the inverter to read the motor speed by virtue of its residual magnetic flux and restart the output
at the corresponding frequency. The inverter can attempt a restart a certain number of times
depending on the particular trip event:

• Over-current trip, restart up to 3 times

• Over-voltage trip, restart up to 3 times

• Under-voltage trip, restart up to 16 times

When the inverter reaches the maximum number of restarts (3 or 16), you must power-cycle the
inverter to reset its operation.

Other parameters specify the allowable under-voltage level and the delay time before restarting.
The proper settings depend on the typical fault conditions for your application, the necessity of
restarting the process in unattended situations, and whether restarting is always safe.

Input

power

Motor

speed

Power failure

Inverter

output

Power failure > allowable power

fail time (B002), inverter trips

Input

power

Motor

speed

Inverter

output

Power failure < allowable power fail

time (B002), inverter resumes

Power failure

Retry wait time

Allowable

power fail time

Allowable

power fail time

free-running

free-running

B002

B003

B002

t

t

0

0

“B” Function

Run

Mode

Edit

Lo Hi

Defaults

Units

SRW Display

Func.

Code

Name

Description

–FE2

(CE)

–FU2

(UL)

–FR

(Jpn)

B001

Selection of automatic
restart mode

Select inverter restart
method, four option codes:
00 Alarm output after trip,

automatic restart
disabled

01 Restart at 0Hz
02 Resume operation after

frequency matching

03 Resume previous freq.

after freq. matching, then
decelerate to stop and
display trip info

✘ ✔

00

00

00

>b001 IPS

POWER ALM

Advertising