Introduction

Oper

ations

a

nd Moni

tor

ing

4–2

Introduction

The previous material in Chapter 3 gave a reference listing of all the programmable functions
of the inverter. We suggest that you first scan through the listing of inverter functions to gain a
general familiarity. This chapter will build on that knowledge in the following ways:

1. Related functions – Some parameters interact with or depend on the settings in other

functions. This chapter lists “required settings” for a programmable function to serve as a
cross-reference and an aid in showing how functions interact.

2. Intelligent terminals – Some functions rely on an input signal from control logic terminals

or generate output signals in other cases.

3. Electrical interfaces – This chapter shows how to make connections between the inverter

and other electrical devices.

4. PID Loop Operation – The L300P has a built-in PID loop that calculates the optimal

inverter output frequency to control an external process. This chapter shows the parameters
and input/output terminals associated with PID loop operation.

5. Multiple motors – A single L300P inverter may be used with two or more motors in some

types of applications. This chapter shows the electrical connections and inverter parameters
involved in multiple-motor applications.

The topics in this chapter can help you decide the features that are important to your applica-
tion, and how to use them. The basic installation covered in Chapter 2 concluded with the
powerup test and running the motor. Now, this chapter starts from that point and shows how to
make the inverter part of a larger control or automation system.

Cautions for
Operating
Procedures

Before continuing, please read the following Caution messages.

CAUTION: The heat sink fins will have a high temperature. Be careful not to touch them.
Otherwise, there is the danger of getting burned.

CAUTION: The operation of the inverter can be easily changed from low speed to high speed.
Be sure check the capability and limitations of the motor and machine before operating the
inverter. Otherwise, it may cause injury to personnel.

CAUTION: If you operate a motor at a frequency higher than the inverter standard default
setting (50Hz/60Hz), be sure to check the motor and machine specifications with the respective
manufacturer. Only operate the motor at elevated frequencies after getting their approval.
Otherwise, there is the danger of equipment damage.