Hitachi L300P User Manual

Page 200

Advertising
background image

Dynamic Braking

Motor Contro

l

Ac

cess

or

ies

5–10

The table below lists the performance of 200V-class inverter models with the optional external
braking units. In some cases, the resistor selection specifies multiple resistors in a parallel,
series, or combination parallel/series configuration. The example diagram shows a parallel
configuration. Please refer to the braking resistor documentation for detailed wiring diagrams.

200V Class

Braking Unit

Dynamic Braking Resistor Selection

Max.

Braking

Torque,

%

Model Number

L300P

Type

Type

x (quantity)

Series or

Parallel

Total

Ohms

Total

Watts

Max.

Duty

Cycle,

%

–185LFU2

BRD–E2

HRB1

50

400

10

25

HRB2

35

600

10

30

HRB3

17

1200

10

50

BRD–E2–30K

HRB3 x (2)

parallel

8.5

2400

20

90

HRB3 x (3)

parallel

5.7

3600

20

130

HRB3 x (4)

parallel

4.3

4800

20

170

–220LFU2

BRD–E2

HRB1

50

400

10

25

HRB2

35

600

10

30

HRB3

17

1200

10

45

BRD–E2–30K

HRB3 x (2)

parallel

8.5

2400

20

80

HRB3 x (3)

parallel

5.7

3600

20

110

HRB3 x (4)

parallel

4.3

4800

20

150

–300LFU2

BRD–E2–30K

HRB3 x (2)

parallel

8.5

2400

20

55

HRB3 x (3)

parallel

5.7

3600

20

80

HRB3 x (4)

parallel

4.3

4800

20

110

–370LFU2

BRD–E2–30K

HRB3 x (2)

parallel

8.5

2400

20

45

HRB3 x (3)

parallel

5.7

3600

20

65

HRB3 x (4)

parallel

4.3

4800

20

90

–450LFU2

BRD–E2–30K

HRB3 x (2)

parallel

8.5

2400

20

35

HRB3 x (3)

parallel

5.7

3600

20

50

HRB3 x (4)

parallel

4.3

4800

20

75

–550LFU2

BRD–E2–30K

HRB3 x (2)

parallel

8.5

2400

20

30

HRB3 x (3)

parallel

5.7

3600

20

40

HRB3 x (4)

parallel

4.3

4800

20

60

–750LFU2

BRD–E2–30K

HRB3 x (2)

parallel

8.5

2400

20

30

HRB3 x (3)

parallel

5.7

3600

20

40

HRB3 x (4)

parallel

4.3

4800

20

60

Braking

Unit

Inverter

Example configuration

HRB3 x (4) parallel