Hitachi L300P User Manual

Page 87

Advertising
background image

“A” Group: Standard Functions

Configur

ing Dr

iv

e

P

a

ra

meters

3–18

Derating of DC Braking – The inverter uses an internal carrier frequency (set by A059) to
generate a DC braking voltage (do not confuse with main inverter output carrier frequency set
by B083). The maximum DC braking force available to the inverter is more limited with higher
DC braking carrier frequency settings for A059 according to the graphs below.

“A” Function

Run

Mode

Edit

Lo Hi

Defaults

Units

SRW Display

Func.

Code

Name

Description

–FE2

(CE)

–FU2

(UL)

–FR

(Jpn)

A051 DC braking enable

Two options; select codes:
00 Disable
01 Enable

✘ ✔

00

00

00

>A051 DCB

Mode OFF

A052 DC braking frequency

setting

The frequency at which DC
braking activates during
decel.
Range is 0.00 to 60.00 Hz

✘ ✔ 0.50 0.50 0.50

Hz

>A052 DCB

F 00.50Hz

A053 DC braking wait time

The delay after reaching the
DC braking frequency, or
[DB] signal, before DC
braking begins.
Range is 0.0 to 5.0 seconds

✘ ✔

0.0

0.0

0.0

sec.

>A053 DCB

WAIT 0.0s

A054 DC braking force during

deceleration

Variable DC braking force.
Range is from 0% to 70%

✘ ✔

0.

0.

0.

%

>A054 DCB

STP-V 000%

A055 DC braking time for

deceleration

Sets the duration for DC
braking during decel. Range
is 0.0 to 60.0 seconds

✘ ✔

0.0

0.0

0.0

sec.

>A055 DCB

STP-T 00.0s

A056 DC braking / edge or

level detection for [DB]
input

Two options; select codes:
00 Edge detection
01 Level detection

✘ ✔

01

01

01

>A056 DCB

KIND LEVEL

A057 DC braking force for

starting

Variable DC braking force.
Range is 0 to 70%

✘ ✔

0.

0.

0.

%

>A057 DCB

STA-V 000%

A058 DC braking time for

starting

Sets the duration for DC
braking before accel.
Range is 0.0 to 60.0 seconds

✘ ✔

0.0

0.0

0.0

sec.

>A058 DCB

STA-T 00.0s

A059 DC braking carrier

frequency setting

Range is 0.5 to 12 kHZ for
models up to –750xxx,
range is 0.5 to 8kHz for
900xxx – 1320xxx models

✘ ✘

3.0

3.0

3.0

kHz

>A059 DCB

CARRIER 05.0kHz

Maximum

braking ratio (%)

10

20

30

40

50

60

70

3

5

7

9

11 12

DC braking carrier frequency

10

20

30

40

50

60

70

3

5

7 8

(10)

(22)

(34)

(46)

(58)

Maximum

braking ratio (%)

DC braking carrier frequency

(10)

(25)

(50)

Models 90 – 132kW

Models 11 – 75kW

kHz

kHz

Advertising