The 04 command reads the status of the inverter.
The frame format of command 04 follows the
diagrams and specification tables. The transmit
frame has no data field.

The receive frame has an 8-byte data field,
containing values for three trip items (plus a
reserved field).

Trip data is organized as shown. The
table below lists the codes and their
meanings.

Element

Description

Size

Value

STX

Control code (STart of TeXt)

1 byte

STX (0x02)

Node

Node (station) address of inverter

2 bytes 01 to 32

Command

Transmission command

2 bytes 04

BCC

Block check sum code

2 bytes Exclusive OR of Node,

Command, and Data

[CR]

Control code (carriage return)

1 byte

[CR] (0x0D)

Element

Description

Size

Value

STX

Control code (STart of TeXt)

1 byte

STX (0x02)

Node

Node (station) address of inverter

2 bytes 01 to 32

Data

Transmission data

8 bytes (see next table)

BCC

Block check sum code

2 bytes Exclusive OR of Node,

Command, and Data

[CR]

Control code (carriage return)

1 byte

[CR] (0x0D)

Code

Status A Definition

Status B Definition

Status C Definition

00

Initial status

On stopping

01

VDC waiting settlement

On running

Stop

02

On Stopping

On tripping

Deceleration speed

03

On running

Constant speed

04

On free-run stop

Acceleration speed

05

On jog

Forward

06

On dynamic braking

Reverse

07

On reading motor freq.

Reverse from forward

08

On retry

Forward from reverse

09

On under-voltage

Forward start

10

On trip

Reverse start

11

On waiting reset

STX Node

Command

BCC [CR]

Transmit frame format

STX Node

Data

BCC [CR]

Receive frame format

Data field contents

(reserved)

Status C

Status B

Status A