L300P Inverter

Configur

ing Dr

iv

e

P

a

ra

met

e

rs

3–61

NOTE: Set frequency (speed) values are not permitted to be inside the jump frequency ranges,
if defined. When a frequency reference value from a real-time source (such as keypad potenti-
ometer or analog input) are inside a jump frequency range, the actual speed is automatically
forced to equal the lowest point of the jump range.

091 291

A061 / A261

Frequency upper limit
setting; 1st, 2nd motor

>

B112

Free-setting V/f frequency (7)

092 292

A062 / A262

Frequency lower limit
setting; 1st, 2nd motor

>

095 295

F001,
A020 / A220

Output frequency setting,
Multi-speed freq. setting;
1st, 2nd motor

>

096

A021 to A035 Multi-speed freq. settings

>

110

B100, B102,
B104, B106,
B108, B110

Free V/f frequency

>

B102, B104,
B106, B108,
B110

Free V/f frequency

>

B100

Free-setting V/f frequency (1)

B100

Free V/f frequency

<

B102

Free-setting V/f frequency (2)

B104, B106,
B108, B110

Free V/f frequency

>

B100, B102

Free V/f frequency

<

B104

Free-setting V/f frequency (3)

B106, B108,
B110

Free V/f frequency

>

B100, B102,
B104

Free V/f frequency

<

B106

Free-setting V/f frequency (4)

B108, B110

Free V/f frequency

>

B100, B102,
B104, B106

Free V/f frequency

<

B108

Free-setting V/f frequency (5)

B110

Free V/f frequency

>

B100, B102,
B104, B106,
B108

Free V/f frequency

<

B110

Free-setting V/f frequency (6)

120

B017, B019

Free-setting electronic
thermal frequency

<

B015

Free-setting, electronic
thermal frequency (1)

B015

Free-setting electronic
thermal frequency

>

B017

Free-setting, electronic
thermal frequency (2)

B019

Free-setting electronic
thermal frequency

<

B015, B017

Free-setting electronic
thermal frequency

>

B019

Free-setting, electronic
thermal frequency (3)

Programming Error

Code

Parameter out of bounds

Boundary defined by...

Code

Description

<, >

Code

Description